ОргТехСервис
Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Коды ошибок Kyocera FS-2100d, FS-2100dn

Error codes Kyocera FS-2100dn

Код ошибки

Содержание Причина Устранение
0100 Backup memory device error Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB.
0120 MAC address data error. For data in which the MAC address is invalid. Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.
0130 Backup memory read/write error (main PWB) Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB.
0140 Backup memory data error (main PWB) Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB.
0150 Backup memory read/write error (engine PWB). Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Check the installation of the EEPROM and remedy if necessary.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Device damage of EEPROM. Contact the Service Administrative Division.
0160 Backup memory data error (engine PWB) Defective EEPROM. Replace the engine PWB and check for correct operation.
Defective engine PWB.
0170 Billing counting error. A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Contact the Service Administrative Division.
Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
0190 Backup memory device error (engine PWB) Defective engine PWB. Replace the engine PWB and check for correct operation
0800 Image processing error. JAM010x is detected twice. Defective main PWB. Replace the main PWB and check for correct operations
0840 Faults of RTC. The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Check visually and remedy if necessary
Defective main PWB. Replace the main PWB and check for correct operation
1010 Lift motor error (60/50/45 ppm model only). After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13)
Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective lift motor. Replace the lift motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
1020 PF lift motor 1 error (paper feeder). After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF lift motor. Replace the PF lift motor 1.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1030 PF lift motor 2 error (paper feeder). After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 2 and PF main PWB (YC7)
Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF lift motor. Replace the PF lift motor 2.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1040 PF lift motor 3 error (paper feeder). After cassette 4 is inserted, PF lift sensor 3 does not turn on. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 3 and PF main PWB (YC7)
Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF lift motor. Replace the PF lift motor 3.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1050 PF lift motor 4 error (paper feeder). After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 4 and PF main PWB (YC7)
Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF lift motor. Replace the PF lift motor 4.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1140 BPF lift motor upward error (Bulk paper feeder) BPF lift maximum sensor does not turn on. The lock signal of the motor is detected continuously three times. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. BPF lift motor and BPF main PWB
Defective drive transmission system of the motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective BPF lift motor. Replace the BPF lift motor.
Defective BPF main PWB. Replace the BPF main PWB (Refer to the service manual for the paper feeder).
1150 BPF lift motor downward error (Bulk paper feeder) BPF lift minimum sensor does not turn on. The lock signal of the motor is detected continuously three times. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. BPF lift motor and BPF main PWB
Defective drive transmission system of the motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective BPF lift motor. Replace the BPF lift motor.
Defective BPF main PWB. Replace the BPF main PWB (Refer to the service manual for the paper feeder).
1800 Paper feeder 1 communication] error. A communication error is detected 10 times in succession. Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and engine PWB (YC22)
Defective engine PWB. Replace the engine PWB and check for correct operation (see page 1-5-22).
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1810 Paper feeder 2 communication error. A communication error is detected 10 times in succession. Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1820 Paper feeder 3 communication error. A communication error is detected 10 times in succession. Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1830 Paper feeder 4 communication error A communication error is detected 10 times in succession. Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
1900 Paper feeder 1/BPF paper feeder EEPROM error. When writing the data, the write data and the read data is not in agreement. Defective PF main PWB. Replace the PF main PWB or the BPF main PWB (Refer to the service manual for the paper feeder).
Device damage of EEPROM.
1910 Paper feeder 2 EEPROM error. When writing the data, the write data and the read data is not in agreement. Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Device damage of EEPROM.
1920 Paper feeder 3 EEPROM error. When writing the data, the write data and the read data is not in agreement. Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Device damage of EEPROM.
1930 Paper feeder 4 EEPROM error. When writing the data, the write data and the read data is not in agreement. Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Device damage of EEPROM.
2000 Main motor drive error. The main motor is not stabilized within 2 s after driving starts. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC4)
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
2010 Main motor steady-state error. Stable OFF is detected for 2 s continuously after main motor stabilized. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC4)
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
2200 Drum motor drive error (60/50/45 ppm model only). The drum motor is not stabilized within 2 s after driving starts. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and engine PWB (YC4)
Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective drum motor. Replace the drum motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
2210 Drum motor steady-state error (60/50/45 ppm model only) Stable OFF is detected for 2 s continuously after drum motor stabilized. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and engine PWB (YC4)
Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective drum motor. Replace the drum motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
2330 Fuser pressure release motor error (Over-current) (60/50/45 ppm model only). The over-current detection signal of the motor is detected continuously twenty times. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and relay-L PWB(YC11) Relay-L PWB and engine PWB(YC2)
Defective drive transmission system of the fuser pressure release motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective fuser pressure release motor. Replace the fuser pressure release motor.
Defective PWB. Replace the relay-L PWB or engine PWB.
2340 Fuser pressure release motor error (Timeout) (60/50/45 ppm model only). The position detection sensor is not detected continuously for 30 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and relay-L PWB(YC11) Relay-L PWB and engine PWB(YC2)
Defective drive transmission system of the fuser pressure release motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective fuser pressure release motor. Replace the fuser pressure release motor.
Defective PWB. Replace the relay-L PWB or engine PWB.
2600 PF drive motor 1 error (paper feeder 1). When the PF drive motor is driven, error signal is detected continuously for 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 1 and PF main PWB (YC6)
Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF drive motor. Replace the PF drive motor 1.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
2610 PF drive motor 2 error (paper feeder 2). When the PF drive motor is driven, error signal is detected continuously for 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 2 and PF main PWB (YC6)
Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF drive motor. Replace the PF drive motor 2.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
2620 PF drive motor 3 error (paper feeder 3). When the PF drive motor is driven, error signal is detected continuously for 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 3 and PF main PWB (YC6)
Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF drive motor. Replace the PF drive motor 3.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
2630 PF drive motor 4 error (paper feeder 4). When the PF drive motor is driven, error signal is detected continuously for 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 4 and PF main PWB (YC6)
Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective PF drive motor. Replace the PF drive motor 4.
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
4000 Polygon motor synchronization error. The polygon motor is not stabilized within 20 s after driving starts. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Polygon motor and engine PWB (YC15)
Defective polygon motor. Replace the laser scanner unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
4200 BD steady-state error. When the value of Register BDSET is 1 after setting Register BDSET as one and passing by BD1 cycle. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PD PWB and engine PWB (YC16)
Defective PD PWB. Replace the laser scanner unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
5100 Chager current error. When the current value measured at the time of potential adjustment is less than 20 pA. When the current values in the chager voltage 500V constitute not less than 85% of target current values. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Chager unit and high voltage PWB High voltage PWB and engine PWB (YC16)
Defective high voltage PWB. Replace the high voltage PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.
6000 Broken fuser heater wire. (60/50/45 ppm model) The detection temperature of fuser thermistor 2 is 100 °C/ 212°F or less after the fuser heater lamp has been turned on continuously for 30 s. (40 ppm model) The detection temperature of fuser thermistor 1 is100°C/ 212°F or less after the fuser heater lamp has been turned on continuously for 30 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser heater and power source PWB (YC2) Fuser thermistor and Fuser thermistor connect PWB Fuser thermistor connect PWB and engine PWB (YC21)
Deformed connector pin. Fix
Defective triac. Replace
Fuser thermostat triggered. Reinsert the fuser unit.
Broken fuser heater wire.
Defective engine PWB. Replace the engine PWB and check for correct operation.
6020 Abnormally high fuser thermistor 2 temperature. The detection temperature of fuser thermistor 2 is higher than 235°C/455°F. In a heater-off state, the detection temperature of fuser thermistor 2 is higher than 195°C/383°F after the detection temperature of fuser thermistor 2 was 155°C/311°F or less. Deformed connector pin. Fix
Defective triac. Replace
Shorted fuser thermistor. Replace the fuser unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
6030 Broken fuser thermistor 2 wire (60/50/45 ppm model only). A/D value of the fuser thermistor 2 exceeds 1019 bit continuously for 4 s during warming up. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB Fuser thermistor connect PWB and engine PWB (YC21)
Deformed connector pin. Fix
Defective triac. Replace
Defective fuser thermistor. Replace the fuser unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
6000/ 6020/ 6030/ 6120/ 6130/ Combined Broken fuser heater wire. Abnormally high fuser thermistor 2 temperature. Broken fuser thermistor 2 wire Deformed connector pin. If the l/F connector pins of the fuser unit and the main unit are deformed owing to foreign matters, replace the connectors or the units including the connectors.
Abnormally high fuser thermistor 1 temperature. Broken fuser thermistor 1 wire Defective triac. Remove the power cord and check that the resistance between terminals T1 and T2 of the triac TRA41 is of several Mega-Ohms and not shorted. If failed, replace the power source PWB.
6120 Abnormally high fuser thermistor 1 temperature. The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. (40 ppm model) The detection temperature of fuser thermistor 1 is higher than 250°C/482°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 170°C/338°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. Deformed connector pin. Fix
Defective triac. Replace
Shorted fuser thermistor. Replace the fuser unit (see page 1-5-19).
Defective engine PWB. Replace the engine PWB and check for correct operation .
6130 Broken fuser thermistor 1 wire. A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB. Fuser thermistor connect PWB and engine PWB (YC21)
Deformed connector pin. Fix
Defective triac. Replace
Defective fuser thermistor. Replace the fuser unit
Defective engine PWB. Replace the engine PWB and check for correct operation
6400 Zero-cross signal error. While fuser heater control is performed, the zero-cross signal is not input within 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Power source PWB (YC3) and engine PWB (YC1)
Defective power source PWB or engine PWB. Replace the power source PWB or the engine PWB and check for correct operation.
7000 Toner motor error. During driving the toner motor, an over-current detection signal is detected at intervals of 10 ms as for 300 accumulation. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner motor and drum PWB (YC4) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
Defective toner motor. Replace the toner motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
7100 Toner sensor error. Sensor output value of 930 or more continuously for 5 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner sensor and drum PWB (YC3) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
Defective toner sensor. Replace the developer unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
7400 Developer unit non-installing error. Sensor output value of 31 or less continuously for 5 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit and drum PWB (YC3) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
Defective toner sensor. Replace the developer unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
7410 Drum unit type mismatch error The drum PWB EEPROM does not communicate normally. Absence of the drum unit is detected. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
Defective toner sensor. Replace the drum unit.
Defective engine PWB. Replace the engine PWB and check for correct operation
7800 Broken external thermistor wire. The average of thermistor output value of 1016 or more continuously for 160 ms. The average of thermistor output value of 930 or more continuously for 5 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
Defective temperature sensor. Replace the operation PWB.
7810 Short-circuited external thermistor wire. The average of thermistor output value of 31 or less continuously for 5 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
Defective temperature sensor. Replace the operation PWB.
7900 Drum unit EEPROM error. No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC15)
Defective drum unit. Replace the drum unit.
F000 Main PWB - operation PWB communication error Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective operation PWB. Replace the operation PWB and check for correct operation.
F010 Main PWB checksum error Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
F020 Main PWB RAM checksum error Defective main memory (RAM) in main PWB Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective expended memory (DIMM) Replace the expansion memory (DIMM). Also in the case of the capacity besides specification, it displays.
F040 Main PWB - print engine communication error Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective engine PWB. Replace the engine PWB and check for correct operation.
F05O Print engine ROM checksum error Defective engine PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace engine PWB.

Kyocera FS-2100 Ошибка 0100, 0120, 0130, 0140, 0150, 0160, 0170, 0190, 0800, 0840, 1010, 1020, 1030, 1040, 1050, 1140, 1150, 1800, 1810, 1820, 1830, 1900, 1910, 1920, 1930, 2000, 2010, 2200, 2210, 2330, 2340, 2600, 2610, 2620, 2630, 4000, 4200, 5100, 6000, 6020, 6030, 6000, 6020, 6030, 6120, 6130, 6400, 7000, 7100, 7400, 7410, 7800, 7810 7900, F000, F010, F020, F040, F05O, Сброс ошибки, Kyocera FS-2100, Kyocera 2100, как сбросить ошибку ?

Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Rambler's Top100 Рейтинг@Mail.ru