ОргТехСервис
Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Коды ошибок Kyocera ECOSYS m3550idn

Код ошибки Содержание ошибки Связанные с ней части мфу Проверка, устранение ошибки
0030 FAX control PWB system error Processing with the fax software was disabled due to a software problem. FAX control PWB 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Reinstall the fax software. 3. Replace the FAX control PWB.
0060 Control PWB mismatch Unmatching engine and engine sub boards. Defective engine subboard Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Replace the control PWB and check for correct operation .
0070 FAX control PWB incompatible detection error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine.) 1. Install the FAX system designed for the model. 2. Reinstall the fax software.
0100 Backup memory device error EEPROM (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB' is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the control PWB and check for correct operation .
0110 Backup memory data error EEPROM (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the control PWB and check for correct operation .
0120 MAC address data error For data in which the MAC address is invalid. EEPROM (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check the MAC address on the network status page. 3. If it is blank, obtain an EEPROM with its MAC address written from the service support and install. 4. Replace the control PWB and check for correct operation .
0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Replace the control PWB and check for correct operation .
0140 Backup memory data error (main NAND) Flash memory (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Replace the control PWB and check for correct operation .
0150 Backup memory read/write error (control PWB) No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively. EEPROM (Control PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM is peroperly installed on the control PWB and reinstall it. 3. Replace the control PWB and check for correct operation . 4. Check the EEPROM and if the data are currupted, contact the service support.
0160 Backup memory data error (control PWB) Reading data from EEPROM is abnormal. EEPROM 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Execute U021 - memory initializing. If the EEPROM data are currupted, contact the service support.
0170 Billing counting error The values on the main circuit PWB and on the engine do not match for any of charging counter, life counter, and scanner counter. EEPROM 1. Check that the EEPROMs installed in the control PWB are correct and, if not, use the correct EEPROM for the model. 2. If the EEPROM data are currupted, contact the service support.
Control PWB Replace the control PWB and check for correct operation .
0180 Machine number mismatch Machine number of control does not match. Data damage of EEPROM 1. Confirm the machine data for the control units by using U004. 2. If the serial number data of different models is alternately displayed, install the correct EEPROM in the PWB of the wrong serial number data. 3. Contact the Service Support.
0190 Backup memory device error (control PWB) Control PWB Replace the control PWB and check for correct operation .
0800 Image processing error JAM010X is detected twice. Control PWB Replace the control PWB and check for correct operation .
0830 FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB. FAX software 1. Reinstall the fax software.
FAX control PWB 1. Execute initializing by U600.(Refer to the FAX service manual) 2. Replace the FAX control PWB.
0840 Faults of RTC (“Time for maintenance T” is displayed) [Check at power up] The RTC setting has reverted to a previous state. The machine has not been powered for 5 years (compared to the settings stored periodically in the EEPROM). Battery (Control PWB) 1. Make sure that the back-up batteries on the control PWB are not short-circuited. 2. If the same C call is displayed when power is switched on and off, replace the back up battery. 3. If communication error (due to a noise, etc.) is present with the RTC on the control PWB, check the PWB is properly grounded.
The RTC setting is older than 00:01 on January 1, 2000. [Checked periodically (in 5-minute interval) after powered up] The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check. Control PWB Replace the control PWB and check for correct operation .
0870 PCFAX control PWB to main PWB high capacity data transfer error High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. FAX control PWB 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Replace the FAX control PWB.
Control PWB Replace the control PWB and check for correct operation .
0920 Fax file system error The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. FAX control PWB 1. Execute initializing by U600 (Refer to the FAX service manual). 2. Replace the FAX control PWB.
0970 24 V power down detect If a 24V power disconnection signal is observed and a 12V power disconnection signal is observed simultaneously for one second. Connect right PWB 1. Check the +24V output is given at YC4-10 to 13 of the connect right PWB. 2. Replace the connect right PWB
Control PWB Replace the control PWB
1010 Lift motor error (50/60 ppm model only) After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively. Bottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and connect right PWB (YC9) Connect right PWB and control PWB (YC29)
Drive transmission system of the lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Lift motor Replace the lift motor.
Connect right PWB Replace the connect right PWB
Control PWB Replace the control PWB and check for correct operation .
1020 PF lift motor 1 error (paper feeder) After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively. Bottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
Drive transmission system of the PF lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF lift motor Replace the PF lift motor 1.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
1030 PF lift motor 2 error (paper feeder) After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected four times successively. Dottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 2 and PF main PWB (YC7)
Drive transmission system of the PF lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF lift motor Replace the PF lift motor 2.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
1040 PF lift motor 3 error (paper feeder) After cassette. 4 is inserted, PF lift sensor 3 does not turn on. This error is detected four times successively. Bottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 3 and PF main PWB (YC7)
Drive transmission system of the PF lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears end replace if any.
PF lift motor Replace the PF lift motor 3.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
1050 PF lift motor 4 error (paper feeder) After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected four times successively. Bottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 4 and PF main PWB (YC7)
Drive transmission system of the PF lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF lift motor Replace the PF lift motor 4.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
1800 Paper feeder 1 communica-tion error A communication error is detected 10 times in succession. Paper feeder Follow installation instruction carefully again.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and control PWB (YC22)
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
Control PWB Replace the control PWB and check for correct operation .
1810 Paper feeder 2 communication error A communication error from paper feeder is detected 10 times in succession. Paper feeder Check the wiring connection status with the main unit and, if necessary, try connecting it again.
PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and control PWB (YC22) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
1820 Paper feeder 3 communication error A communication error from paper feeder is detected 10 times in succession. Paper feeder Check the wiring connection status with paper feeder unit 2 and, if necessary, try connecting it again.
PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and PF main PWB (YC22). 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
1830 Paper feeder 4 communication error A communication error from paper feeder is detected 10 times in succession. Paper feeder Check the wiring connection status with paper feeder unit 3 and, if necessary, try connecting it again.
PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and PF main PWB (YC22). 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
1900 Paper feeder 1 EEPROM error When writing the data, read and write data does not match 4 times in succession. PF main PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
1910 Paper feeder 2 EEPROM error When writing the data, read and write data does not match 4 times in succession. PF main PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in.Replace the PF main PWB.
1920 Paper feeder 3 EEPROM error When writing the data, read and write data does not match 4 times in succession. PF main PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
1930 Paper feeder 4 EEPROM error When writing the data, read and write data does not match 4 times in succession. PF main PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
2000 Main motor startup error Main motor is not stabilized within 2 s since the motor is activated. Main motor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Main motor and connect right PWB (YC10) Connect right PWB and control PWB (YC29) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the main motor.
Connect right PWB Replace the cconnect right PWB .
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
2010 Main motor steady-state error After main motor is stabilized, the ready signal is not ready for 2 s continuously. Main motor 1. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Main motor and connect rightl PWB (YC10) Connect right PWB and control PWB (YC29) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the main motor.
Connect right PWB Replace the connect right PWB .
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
2200 Drum motor drive error (50/60 ppm model only) The drum motor is not stabilized within 2 s after driving starts. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and connect right PWB (YC10) Connect right PWB and control PWB (YC29)
Drive transmission system of the drum motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Drum motor Replace the drum motor.
Connect right PWB Replace the connect right PWB.
Control PWB Replace the control PWB and check for correct operation .
2210 Drum motor steady-state error (50/60 ppm model only) Stable OFF is detected for 2 s continuously after drum motor stabilized. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and connect right PWB (YC10) Connect right PWB and control PWB (YC29)
Drive transmission system of the drum motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Drum motor Replace the drum motor.
Connect right PWB Replace the connect right PWB.
Control PWB Replace the control PWB and check for correct operation .
2330 Envelope motor error (Over-current) (50/60 ppm model only) The over-current detection signal of the motor is detected continuously twenty times. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Envelope motor and connect left PWB (YC11) Connect left PWB and control PWB (YC2)
Drive transmission system of the envelope motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Envelope motor Replace the envelope motor.
Connect left PWB. Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation .
2340 Envelope motor error (Timeout) (50/60 ppm model only) The position detection sensor is not detected continuously for 30 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Envelope motor and connect left PWB (YC11) Connect left PWB and control PWB (YC2)
Drive transmission system of the envelope motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Envelope motor Replace the envelope motor.
Connect left PWB Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation .
2600 PF drive motor 1 error (paper feeder 1) When the PF drive motor is driven, error signal is detected continuously for 2 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 1 and PF main PWB (YC6)
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
DPF drive motor Replace the PF drive motor 1.
DPF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
2610 PF drive motor 2 error (paper feeder 2) When the PF drive motor is driven, error signal is detected continuously for 2 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 2 and PF main PWB (YC6)
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF drive motor Replace the PF drive motor 2.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
2620 PF drive motor 3 error (paper feeder 3) When the PF drive motor is driven, error signal is detected continuously for 2 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 3 and PF main PWB (YC6)
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF drive motor Replace the PF drive motor 3.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
2630 PF drive motor 4 error (paper feeder 4) When the PF drive motor is driven, error signal is detected continuously for 2 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 4 and PF main PWB (YC6)
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF drive motor Replace the PF drive motor 4.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
3100 Scanner carriage error The home position is not correct when the power is turned on, at the end of a reading process of the table and document processor. Image scanner motor 1. Move the scanner by the hand to check whether it is unusually difficult to move. 2. Check that the scanner driving belt is not disengaged. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Image scanner motor and control PWB (YC1002) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the image scanner motor.
Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Home position sensor and CCD PWB (YC3) CCD PWB and control PWB (YC1000) 3. Replace the home position sensor.
CCD PWB Replace the image scanner unit and execute U411.
Control PWB Replace the control PWB and check for correct operation .
3200 Exposure lamp error When a lamp is made to turn on one side at a time, the white standard data at the time of an initial is lower than a rated value. LED PWB 1. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. LED PWB and CCD PWB (YC2) CCD PWB and control PWB (YC1000) 2. Replace the image scanner unit.
CCD PWB Replace the image scanner unit and execute U411.
Control PWB Replace the control PWB and check for correct operation .
3500 Communication error between scanner and ASIC An error code is detected. CCD PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CCD PWB and control PWB (YC1000) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the image scanner unit and execute U411.
Control PWB Replace the control PWB and check for correct operation .
4000 Polygon motor steady-state error After Polygon motor is stabilized, the ready signal is at the H level for 20 s continuously. Polygon motor (LSU) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Laser scanner unit and control PWB (YC15) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the laser scanner unit.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
4200 BD steady-state error The BD signal is not detected. PD PWB (LSU) 1. Confirm that the FCC wiring connector is not distorted and connect the FCC wiring all the way in. Laser scanner unit and control PWB (YC16) 2. If the FCC wiring is disconnected, shorted or grounded, replace the FCC wiring. 3. Replace the laser scanner unit.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
5100 Chager current error When the current value measured at the time of potential adjustment is'less than 20 pA. The error of the charge current before toner installation. The error of the charge current before printing. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Chager unit and high voltage PWB High voltage PWB and control PWB (YC19)
High voltage PWB Replace the high voltage PWB and check for correct operation.
Control PWB Replace the control PWB and check for correct operation .
6000 Broken fuser heater wire (Center) (50/60 ppm model) Fuser thermistor 2 detects a temperature less than 100°C/ 212°F continuously for 30 s after a warm-up start. (40 ppm model) Fuser thermistor 1 detects a temperature less than 100°C/ 212°F continuously for 30 s after a warm-up start. Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser thermistor connect PWB (YC2) Fuser thermistor connect PWB and control PWB (YC21) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit. (Deteriorated sensitivity due to the toner adhered to the center thermistor.)
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
Power source PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Power source PWB and connect right PWB (YC4) Connect right PWB and control PWB (YC1) 2. Replace the power source PWB.
Fuser heater 1. Replace the Fuser unit.
6020 Abnormally high fuser thermistor 2 temperature (Center) (50/60 ppm model only) Fuser thermistor 2 detects a temperature higher than 235°C/455°F. In a heater-off state, the detection temperature of fuser thermistor 2 is higher than 195°C/383°F after the detection temperature of fuser thermistor 2 was 155°C/311 °F or less. Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser thermistor connect PWB (YC2) Fuser thermistor connect PWB and control PWB (YC21) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
6030 Broken fuser thermistor 2 wire (Center) (50/60 ppm model only) Input from fuser thermistor 2 is 1019 or more (A/D value) continuously for 4 s. Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser thermistor connect PWB (YC2) Fuser thermistor connect PWB and control PWB (YC21) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit. (Deteriorated sensitivity due to the toner adhered to the center thermistor.)
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB .
Fuser thermistor 2 1. Replace the Fuser unit.
Fuser thermostat (triggered) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and power source PWB (YC2) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit.
Power source PWB Replace the power source PWB .
6000 Broken fuser heater wire Abnormally high fuser thermistor 2 temperature Broken fuser thermistor 2 wire Abnormally high fuser thermistor 1 temperature Broken fuser thermistor 1 wire Connector pin If the l/F connector pins of the fuser unit and the main unit are deformed owing to foreign matters, replace the connectors or the units including the connectors.
6020
6030
6120 Triac Remove the power cord and check that the resistance between terminals T1 and T2 of the triac TRA31 and triac TRA41 (the triac TRA41 is 60/50 ppm model only) are of several Mega-Ohms and not shorted.
6130
Com- bined
6120 Abnormally high fuser thermistor 1 temperature (50/60 ppm model) The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. (40 ppm model) The detection temperature of fuser thermistor 1 is higher than 250°C/482°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 170°C/338°F after the detection temperature of fuser thermistor 1 was 155Х/311 °F or less. . Connector pin Check
Triac Check
Fuser thermistor Replace the fuser unit.
Contrl PWB Replace the control PWB and check for correct operation .
6130 Broken fuser thermistor 1 wire (50/60 ppm model only) AID value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB (YC1) Fuser thermistor connect PWB and control PWB (YC21)
Connector pin Check
Triac Check
Fuser thermistor Replace the fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB Replace the control PWB and check for correct operation .
6120 Abnormally high fuser thermistor 1 temperature (50/60 ppm model) The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. (40 ppm model) The detection temperature of fuser thermistor 1 is higher than 250°C/482°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 170°C/338°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. . Connector pin Check
Triac Check
Fuser thermistor Replace the fuser unit.
Contrl PWB Replace the control PWB and check for correct operation .
6130 Broken fuser thermistor 1 wire (50/60 ppm model only) A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB (YC1) Fuser thermistor connect PWB and control PWB (YC21)
Connector pin Check
Triac Check
Fuser thermistor Replace the fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB Replace the control PWB and check for correct operation .
6400 Zero-cross signal error While fuser heater ON/OFF control is performed, the zero-cross signal is not input within 2 s. Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Power source PWB and connect right PWB (YC4) Connect right PWB and control PWB (YC29) 2. If the wiring is disconnected, shorted or grounded, replace the wiring.
Power source PWB Replace the power source PWB .
Connect right PWB Replace the connect right PWB .
Control PWB Replace the control PWB .
7000 Toner motor error During driving the toner motor, an over-current detection signal is detected at intervals of 10 ms as for 300 accumulation. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner motor and drum PWB (YC4) Drum PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC3)
Drum unit Replace the drum unit.
Connect left PWB Replace the connect left PWB .
Control PWB Replace the control PWB and check for correct operation .
7100 Toner sensor error Sensor output value of 930 or more continuously for 5 s. Toner sensor 1. Check the toner sensor output. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner sensor and drum PWB (YC3) Drum PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC3) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Check that the gears of the Developer unit are not damaged and the spiral.
Toner motor 1. Draw out the toner container. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor and drum PWB (YC4) Drum PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC3) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor.
Connect left PWB Replace the connect left PWB .
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
7400 Developer unit non-installing error Sensor output value of 31 or less continuously for 5 s. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit and drum PWB (YC3) Drum PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC2)
Toner sensor Replace the developer unit.
Connect left PWB Replace the connect left PWB .
Control PWB Replace the control PWB and check for correct operation .
7410 Drum unit type mismatch error The drum PWB EEPROM does not communicate normally. Absence of the drum unit is detected. Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC2)
Toner sensor Check
Connect left PWB Replace the connect left PWB .
Control PWB Replace the control PWB and check for correct operation .
7800 Broken temperature sensor wire Input from temperature sensor is 1019 or more continuously for 160 ms. Input from temperature sensor is 930 or more continuously for 5 s. Temperature sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Temperature sensor and control PWB (YC30) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the key right PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
7810 Short-circuited temperature sensor wire Input from temperature sensor is 31 or less continuously for 5 s. Temperature sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Temperature sensor and control PWB (YC30) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the key right PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
7900 Drum EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively. DR PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DR PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC2) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Drum unit.
Connect left PWB Replace the connect left PWB .
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation .
F000 Communication error between Control PWB and Operation PWB Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the wirings and connetors between the control PWB and the operation panel PWB are normal. Operation PWB and control PWB (YC2002) 3. Check that the DIMM memories in the control PWB are well conducted and, if not, replace. 4. Execute U021 initialize memory, 5. Replace the control PWB.
Operation PWB Replace the operation PWB.
F010 Control PWB checksum error Control PWB Turn the main power switch off/on to restart the machine. If the error is not resolved, replace control PWB and check for correct operation .
F020 Control PWB RAM check sum error Main memory (RAM) Turn the main power switch off/on to restart the machine. If the error is not resolved, replace control PWB and check for correct operation .
F040 Communication error between Controller and Print engine Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Repair or replace the wire from the control PWB, that may be grounded. (Check short-circuit between 5V and 3.3V.) 3. Check the control software and upgrade to the latest, if necessary. 4. If not corrected, replace the control PWB and check for correct operation .
F041 Communication error between Controller and Scan engine Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Repair or replace the wire from the control PWB, that may be grounded. (Check short-circuit between 5V and 3.3V.) 3. Check the control software and upgrade to the latest, if necessary. 4. If not corrected, replace the control PWB and check for correct operation .
F050 Print engine ROM checksum error Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Confirm that the EEPROM has been properly installed. 3. Check the control software and upgrade to the latest, if necessary. 4. If not corrected, Replace the control PWB and check for correct operation .
F051 Scan engine ROM checksum error Control PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Confirm that the EEPROM has been properly installed. 3. Check the control software and upgrade to the latest, if necessary. 4. If not corrected, Replace the control PWB and check for correct operation .

Kyocera ECOSYS m3550idn ошибки передачи данных

Код ошибки Описание
U00000 No response or busy after the set number of redials.
U00100 Transmission was interrupted by a press of the stop/clear key.
U00200 Reception was interrupted by a press of the stop/clear key.
U00300 Recording paper on the destination unit has run out during transmission.
U004XX A connection was made but interrupted during handshake with the receiver unit.
U00500 Multiple communication was interrupted and call was not made on destination units after interruption.
U006XX Communication was interrupted because of a machine problem.
U00700 Communication was interrupted because of a problem in the destination unit.
U008XX A page transmission error occurred in G3 mode.
U009XX A page reception error occurred in G3 mode.
U010XX Transmission in G3 mode was interrupted by a signal error.
U011XX Reception in G3 mode was interrupted by a signal error.
U01400 An invalid one-touch key was specified during communication.
U01500 A communication error occurred when calling in V.8 mode.
U01600 A communication error occurred when called in V.8 mode.
U017XX A communication error occurred before starting T.30 protocol during transmission in V.34 mode.
U018XX A communication error occurred before starting T.30 protocol during reception in V.34 mode.
U02000 Relay broadcast was refused by a relay station because of a mismatch in permit ID number and permit telephone number when a relay command was issued.
U02100 A relay command failed because the destination unit (relay station) had no relay broadcast capability.
U02200 A relay command from a command station failed because a telephone number that was not registered in the relay station was specified. Or, relay broadcast was requested to a relay station but failed because a telephone number that was not registered in the relay station was specified. Or, Subaddress-based relay broadcast transmission failed because the data registered in the Subaddress relay box was deleted.
U023XX Receiving station information was not normally received in reception of a relay command.
U02400 An interoffice subaddress-based relay transmission was interrupted because of a mismatch in the specified relay box number.
U03000 No document was present in the destination unit when polling reception started.
U03100 In reverse polling, although, no original was set in the destination unit, transmission was complete.
U03200 In confidential polling reception, data was not accumulated in the specified box in the destination unit. Or, in interoffice subaddress-based bulletin board reception, data was not stored in the box specified by the destination unit.
U03300 In polling reception from a unit of our make, operation was interrupted due to a mismatch in permit ID or telephone number. Or, in interoffice subaddress-based bulletin board reception, operation was interrupted due to a mismatch in permit ID or telephone number.
U03400 Polling reception was interrupted because of a mismatch in individual numbers (destination unit is either of our make or by another manufacturer).
U03500 In confidential polling reception, the specified confidential box No. was not registered in the destination. Or, in interoffice subaddress-based bulletin board reception, the specified Subaddress confidential box number was not registered in the destination unit. Or, the destination was being accessed.
U03600 Confidential polling reception was interrupted because of a mismatch in specified confidential box No. Or, an interoffice subaddress-based bulletin board reception was interrupted because of a mismatch in the specified subaddress confidential box number.
U03700 Confidential polling reception failed because the destination unit had no confidential polling transmission capability or data was not accumulated in any box in the destination unit. Or, interoffice subaddress-based bulletin board reception failed because the destination unit had no subaddress-based bulletin board transmission capability, or data was not stored in any subaddress confidential box in the destination unit.
U04000 The confidential box specified for confidential transmission was not registered in the destination unit. Or, in interoffice subaddress-based transmission mode, the specified subaddress box number was not registered in the destination unit. Or, the destination was being accessed.
U04100 Confidential transmission failed because the destination unit had no confidential capability. Or, subaddress-based transmission failed because the destination unit had no subaddress-based reception capability.
U04200 In encrypted transmission, the specified encryption box was not registered in the destination unit.
U04300 Encrypted transmission failed because the destination unit had no encrypted communication capability.
U044XX Communication was interrupted because of an encryption key error during encrypted transmission.
U04500 Encrypted reception was interrupted because of a mismatch in encryption keys.
U05000 In transmission with a specified number, the set number of originals was different from the number of transmitted originals.
U05100 Password check transmission or restricted transmission was interrupted because the permit ID's did not agree with.
U05200 Password check reception or restricted reception was interrupted because the permit ID’s did not match, the rejected FAX number’s did match, or the destination receiver did not return its phone number.
U05300 The password check reception or the restricted reception was interrupted because the permitted numbers did not match, the rejected numbers did match, or the machine in question did not acknowledge its phone number.
U09000 G3 communication was attempted but failed because the destination unit was a G2 machine.
U12000 Relay broadcast was requested from a command station but memory overflowed during reception. Or, in subaddress-based relay reception, memory overflowed.
u12100 Relay was commanded but memory overflowed in the destination unit (relay station).
U14000 Memory overflowed during confidential reception. Or, in subaddress-based confidential reception, memory overflowed.
U14100 Memory overflowed in the destination unit during confidential transmission. Or, in interoffice subaddress-based transmission, memory overflowed in the destination unit.
U19000 Memory overflowed during memory reception.
U19100 Memory overflowed in the destination unit during transmission.
U19200 Memory transmission failed because a decoding error occurred.
U19300 Transmission failed because an error occurred during JBIG encoding.
U19400 Reception failed because an error occurred during JBIG decoding.
U00420 A relay request was received from the host center but interrupted because of a mismatch in permit ID or telephone number.
U00421 Subaddress-based relay reception was interrupted because of a mismatch in the specified subaddress relay box number.
U00430 Polling request (confidential or reverse) was received but interrupted because of a mismatch in permit number. Or, subaddress-based bulletin board transmission request was received but interrupted because of a mismatch in permit ID in the transmitting unit.
U00431 Confidential polling transmission was interrupted because the specified confidential box No. was not registered. Or, an subaddress-based bulletin board transmission was interrupted because the specified subaddress confidential box was not registered.
U00432 Confidential polling transmission was interrupted because of a mismatch in confidential box ID number. Or, an subaddress-based bulletin board transmission was interrupted because of a mismatch in Subaddress confidential box numbers.
U00433 Confidential polling request was received but data was not present in the confidential box. Or, subaddress-based bulletin board transmission request was received but data was not present in the subaddress confidential box.
U00434 Confidential polling request was received but interrupted because the specified confidential box No. was intended for encryption.
U00435 Confidential polling request was received but interrupted because the specified confidential box was being accessed. Or, subaddress-based bulletin board transmission request was received but interrupted because the specified subaddress confidential box was being accessed.
U00440 Confidential reception was interrupted because the specified confidential box No. was not registered. Or, subaddress-based confidential reception or subaddress-based relay reception was interrupted because the specified subaddress box was not registered. Or, subaddress based confidential reception or subaddress relay command reception was interrupted because the specified subaddress box No. was being accessed.
U00441 Confidential reception was interrupted because the specified confidential box No. was intended for encryption.
U00450 The destination transmitter disconnected because the permit ID’s did not agree with while the destination transmitter is in password-check transmission or restricted transmission.
U00460 Encrypted reception was interrupted because the specified encryption box number was not registered. Or, encrypted reception request was received but interrupted because the specified encryption box was being accessed.
U00462 Encrypted reception was interrupted because the encryption key for the specified encryption box was not registered.
U00600 The document processor cover is open.
U00601 Document jam or the document length exceeds the maximum.
U00602 Image scanning section problem.
U00603 No document feed.
U00604 Document length exceeded the limit of the bitmap memory capacity.
U00610 Recording section cover is open.
U00611 Recording paper JAM
U00613 Image writing section problem
U00614 Nearly empty of recording paper
U00615 Empty of recording paper
U00620 Copier fixing unit problem
U00622 Copier drive motor problem
U00655 CTS was not activated after RTS due to a modem error.
U00656 Data was not transmitted after CTS was activated due to a modem error.
U00670 Power was cut off during communication.
U00677 There was no file to transmit in the memory transmission mode.
U00690 System error.


(2-3) U008XX error code table: Page transmission error


Error code Description
U00800 A page transmission error occurred because of reception of a RTN or PIN signal.
U00810 A page transmission error reoccurred after retry of transmission in the ECM mode.


(2-4) U009XX error code table: Page reception error


Error code Description
U00900 An RTN or PIN signal was transmitted because of a page reception error.
U00910 A page reception error remained after retry of transmission in the ECM mode.


(2-5) U010XX error code table: G3 transmission


Error code Description
U01000 An FTT signal was received for a set number of times after TCF signal transmission at 2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP) after transmission at 2400 bps.
U01001 Function of the unit differs from that indicated by a DIS signal.
U01010 No relevant signal was received after transmission of a DNL (MPS or EOM) signal, and the preset number of command retransfers was exceeded (between units of our make).
U01011 No relevant signal was received after transmission of a DCS, TCF signal, and the preset number of command retransfers was exceeded.
U01012 No relevant signal was received after transmission of an NSS1, NSS2 (TCF) signal, and the preset number of command retransfers was exceeded (between units of our make).
U01013 No relevant signal was received after transmission of an NSS3, TCF signal, and the preset number of command retransfers was exceeded (between units of our make).
U01014 No relevant signal was received after transmission of an MPS signal, and the preset number of command retransfers was exceeded.
U01015 No relevant signal was received after transmission of an EOM signal, and the preset number of command retransfers was exceeded.
U01016 An MCF signal was received but no DIS signal was received after transmission of an EOM signal, and T1 timeout was detected.
1)01017 No relevant signal was received after transmission of an EOP signal, and the preset number of command retransfers was exceeded.
U01018 No relevant signal was received after transmission of a PRI-EOP signal, and the preset number of command retransfers was exceeded.
U01019 No relevant signal was received after transmission of a CNC signal, and the preset number of command retransfers was exceeded (between units of our make).
U01020 No relevant signal was received after transmission of a CTC signal, and the preset number of command retransfers was exceeded (ECM).
U01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset number of command retransfers was exceeded (ECM).
U01022 NO' relevant signal was received after transmission of an RR signal, and the preset number of command retransfers was exceeded (ECM).
U01023 No relevant signal was received after transmission of a PSS.NULL signal, and the preset number of command retransfers was exceeded (ECM).
U01024 No relevant signal was received after transmission of a PSS.MPS signal, and the preset number of command retransfers was exceeded (ECM).
U01025 No relevant signal was received after transmission of a PPS.EOM signal, and the preset number of command retransfers was exceeded (ECM).
U01026 No relevant signal was received after transmission of a PPS.EOP signal, and the preset number of command retransfers was exceeded (ECM).
U01027 No relevant signal was received after transmission of a PPS.PRI-EOP signal, and the preset number of command retransfers was exceeded (ECM).
U01028 T5 time-out was detected during ECM transmission (ECM).
U01040 A DCN or other inappropriate signal was received during standby for DIS signal reception.
U01041 A DCN signal was received after transmission of a DNL (MPS or EOM) signal (between units of our make).
U01042 A DCN signal was received after transmission of a DCS, TCF signal.
U01043 A DCN signal was received after transmission of an NSS1, NSS2 (TCF) signal (between units of our make).
U01044 A DCN signal was received after transmission of an NSS3, TCF signal (between units of our make).
U01045 A DCN or other inappropriate signal was received after transmission of an MPS signal.
U01046 A DCN or other inappropriate signal was received after transmission of an EOM signal.
U01047 A DCN or other inappropriate signal was received after transmission of an EOP signal.
U01048 A DCN signal was received after transmission of a PRI-EOP signal.
U01049 A DCN signal was received after transmission of a CNC signal (between units of our make).
U01050 A DCN signal was received after transmission of a CTC signal (ECM).
U01051 A DCN signal was received after transmission of an EOR.Q signal (ECM).
U01052 A DCN signal was received after transmission of an RR signal (ECM).
U01053 A DCN signal was received after transmission of a PPS.NULL signal (ECM).
U01054 A DCN signal was received after transmission of a PPS.MPS signal (ECM).
U01055 A DCN signal was received after transmission of a PPS.EOM signal (ECM).
U01056 A DCN signal was received after transmission of a PPS.EOP signal (ECM).
U01057 A DCN signal was received after transmission of a PPS.PRI-EOP signal (ECM).
U01070 Polarity reversal was detected during handshake.
U01071 Polarity reversal was detected during message transmission.
U01072 A break in loop current was detected during transmission.
U01073 During reverse polling in V.34 mode at the receiver unit, a CM signal was not detected when transmitting after reception.
U01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01091 During transmission in V.34 mode, communication was interrupted because a PPR signal was received over 10 times even after reducing the communication speed to the minimum with the symbol speed maintained at the level of connection.
U01092 During transmission in V.34 mode, communication was interrupted because of an impossible combination of the symbol speed and communication speed.


(2-6) U011XX error code table: G3 reception


Error code Description
U01100 Function of the unit differs from that indicated by a DCS signal.
U01101 Function of the unit (excl. communication mode select) differs from that indicated by an NSS signal.
U01102 A DTC (NSC) signal was received when no transmission data was in the unit.
U01110 No response after transmission of a DIS signal.
U01111 No response after transmission of a DTC (NSC) signal.
U01112 No training reception after reception of a DCS or NSS signal.
U01113 No response after transmission of an FTT signal.
U01114 No message reception after transmission of a CFR signal.
U01115 No message reception after transmission of an MCF signal.
U01116 No message reception after transmission of a PPR signal.
U01117 No message reception after transmission of a CTR signal.
U01118 No message reception after transmission of an ERR signal.
U01119 No further signals were received after reception of a message.
U01120 No response after transmission of an MCF signal.
U01121 No response after transmission of an RTP signal.
U01122 No response after transmission of an RTN signal.
U01123 No response after transmission of a PIP signal.
U01124 No response after transmission of a PIN signal.
U01125 No response after transmission of a CNS signal (between units of our make).
U01126 No response after transmission of a PPR signal (ECM).
U01127 No response after transmission of an ERR signal (ECM).
U01128 No response after transmission of an RNR signal (ECM).
U01129 No response after transmission of an SPA signal (short protocol).
U01140 A DCN signal was received after transmission of a DIS signal.
U01141 A DCN signal was received after transmission of a DTC signal.
U01142 A DCN signal was received after transmission of a DCS or NSS signal.
U01143 A DCN signal was received after transmission of an FTT signal.
U01144 A DCN signal was received after transmission of a CFR signal.
U01145 A DCN signal was received after reception of a message.
U01146 A DCN signal was received after transmission of an MCF signal (interoffice communication after reception of an MPS, EOM signal or confidential interoffice communication).
U01147 A DCN signal was received after transmission of an RTP signal.
U01148 A DCN signal was received after transmission of an RTN signal.
U01149 A DCN signal was received after transmission of a PIP signal.
U01150 A DCN signal was received after transmission of a PIN signal.
U01151 A DCN signal was received after transmission of a PPR signal (ECM).
U01152 A DCN signal was received after transmission of a CTR signal (ECM).
U01153 A DCN signal was received after transmission of an ERR signal (ECM).
U01154 A DCN signal was received after transmission of an RNR signal (ECM).
U01155 A DCN signal was received after transmission of an SPA signal (short protocol).
U01160 During message reception, transmission time exceeded the maximum transmission time per line.
U01161 Number of error lines exceeded limits during message reception.
U01162 A break in loop current was detected during message reception.
U01163 Polarity reversal was detected during message reception.
U01164 One page length exceeded the specified length during message reception.
U01170 A decoding error occurred during MMR message reception.
U01172 During reverse polling in V.34 mode at the transmitting unit, a JM signal was not detected after transmission of a CM signal when receiving after transmission.
U01191 Communication was interrupted because an error occurred during an image data reception sequence in the V.34 mode.
U01199 A DIS signal with different FIF was received after transmission of a DIS signal.


(2-7) U017XX error code table: V.34 transmission


Error code Description
U01700 A communication error occurred in phase 2 (line probing).
U01720 A communication error occurred in phase 4 (modem parameter exchange).
U01721 Operation was interrupted due to the absence of a common communication speed between units.
U01700: A communication error that occurs at the transmitting unit in the period after transmission of INFOO before entering phase 3 (primary channel equivalent device training). For example, INFOO/A/Abar (B/Bbar, forpolling transmission)/INFOh was not detected.
U01720: A communication error that occurs at the transmitting unit in the period after initiating the control channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected.
U01721: In the absence of a common communication speed between units (including when an impossible combination of communication speed and symbol speed occurs) after MPh exchange; 1) a DCN signal was received from the destination unit, and the line was cut; or 2) a DIS (NSF, CSI) signal was received from the destination unit and, in response to the signal, the unit transmitted a DCN signal,- and the line was cut.




(2-8) U018XX error code table: V.34 reception


Error code Description
U01800 A communication error occurred in phase 2 (line probing).
U01810 A communication error occurred in phase 3 (primary channel equivalent device training).
U01820 A communication error occurred in phase 4 (modem parameter exchange).
U01821 Operation was interrupted due to the absence of a common communication speed between units.
U01800: A communication error that occurs at the receiver unit in the period after transmission of INFOO before entering phase 3 (primary channel equivalent device training). For example, INFOO/B/Bbar (A/Abar, for polling reception)/probing tone was not detected.
U01810: A communication error that occurs at the receiver unit in phase 3 (primary channel equivalent device training). For example, S/Sbar/PP/TRN was not detected.
U01820: A communication error that occurs at the receiver unit in the period after initiating the control channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected.
U01821: In the absence of a common communication speed between units (including when an impossible combination of communication speed and symbol speed occurs) after MPh exchange, a DCN signal was transmitted to the destination unit and the line was cut.


(2-9) U023XX error code table: Relay command abnormal reception


Error code Description
U02303 Timeout was detected before a correct DNL signal was received.
U02304 A signal other than MPS or EOM signal was received after a DNL signal was received.


(2-10) U044XX error code table: Encrypted transmission


Error code Description
U04400 Encrypted transmission was interrupted because encryption keys did not agree.
U04401 Calling failed during encrypted transmission because the encryption key was not registered.

Kyocera Ecosy m3550idn коды ошибок, Kyocera m3550 ошибка, Kyocera 3550 ошибка 0030, 0060, 0070, 0100, 0110, 0120, 0130, 0140, 0150, 0160, 0170, 0180, 0190, 0800, 0830, 0840, 0870, 0920, 0970, 1010, 1020, 1030, 1040, 1050, 1800, 1810, C5100, С6120, C7905, F000, F020, F040, F041, F050, F051, F245, F247, F248, cF000, cF020, cF040, cF041, cF050, cF051 Kyocera Ecosys m3550idn ошибка, m3550idn, Kyocera m3550idn ошибка , Kyocera 3550 сброс ошибки

как сбросить ошибку, сброс, Kyocera 3550 ошибка, сброс ошибки, как сбросить ошибку ?

Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Rambler's Top100 Рейтинг@Mail.ru