Error Codes Canon i-SENSYS MF216
|
Код ошибки
|
Описание
|
Устранение
|
E000-0000
|
Fixing Assembly does not start up within specified time.
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater
resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly
when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 U ±7% [2] 230 V machines - Heater resistance: 53.8 U ±7% 2.
Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4.
Replace the Fixing Assembly. 5. Replace the DC Controller Board.
|
E001-0000
|
Abnormal hightemperature detection
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater
resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly
when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 U ±7% [2] 230 V machines - Heater resistance: 53.8 U ±7% 2.
Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4.
Replace the Fixing Assembly. 5. Replace the DC Controller Board.
|
E003-0000
|
Abnormal lowtemperature detection
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater
resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly
when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 U ±7% [2] 230 V machines - Heater resistance: 53.8 U ±7% 2.
Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4.
Replace the Fixing Assembly. 5. Replace the DC Controller Board.
|
E004-0000
|
Fixing power supply drive circuit error
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the DC
Controller Board. 2. Replace the Fixing Assembly.
|
E100-0001
|
Error detection on any of scanner motor, laser unit, and BD detection at scanner area.
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the Laser
Scanner Unit. 2. Replace the DC Controller Board.
|
E196-2000
|
ROM read/write error (Error in storing each setting values for user mode / service mode / factory mode)
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Update the set of the
Controller Firmware 2. Replace the Main Controller Board.
|
E202-0002
|
Contact Sensor HP error, Failure in return
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the connection
of Flat Cable between Main Controller Board (J5) and Contact Sensor. 2. Replace the Flat Cable between Main Controller Board (J5) and Contact
Sensor. 3. Replace the Contact Sensor. 4. Replace the Main Controller Board.
|
E225-0001
|
Light intensity of a lamp is less or equal to the criteria
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the connection
of Flat Cable between Main Controller Board (J5) and Contact Sensor. 2. Replace the Flat Cable between Main Controller Board (J5) and Contact
Sensor. 3. Replace the Contact Sensor. 4. Replace the Main Controller Board.
|
E301-0001
|
Insufficient light intensity in shading
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the connection
of Flat Cable between Main Controller Board (J5) and Contact Sensor. 2. Replace the Flat Cable between Main Controller Board (J5) and Contact
Sensor. 3. Replace the Contact Sensor. 4. Replace the Main Controller Board
|
E736-0000
|
Communication error with CCU/modem, or no FAX board installed on FAX model.
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the connection
of connectors between the Main Controller Board (J601, J602) and the FAX-NCU Board (J1201, J1204). 2. Replace the connectors between the Main
Controller Board (J601, J602) and the FAX-NCU Board (J1201, J1204). 3. Replace the FAX-NCU Board. 4. Replace the Main Controller Board.
|
E740-0002
|
Error detection on either Network Board or Mac address
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the connection
of the network cable. 2. Replace the Main Controller Board.
|
E744-0002
|
Language file error
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. Update the set of the
Controller Firmware
|
E744-4000
|
Engine ID error (Invalid engine connection is detected)
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check the DC
Controller Board. 2. Update the Engine Firmware. 3. Update the set of the Controller Firmware
|
E744-6000
|
Communication error with Wireless LAN board.
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the Wireless
LAN Board. 4. Replace the Main Controller Board.
|
E806-0000
|
Fan Motor cannot rotate at specified revolution speed.
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the Main Fan
Unit. 2. Replace the DC Controller Board.
|
E808-0001
|
Fixing Assembly_Edge Left Cooling Fan error
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the Edge Left
Cooling Fan. 2. Replace the DC Controller Board.
|
E808-0002
|
Fixing Assembly_Edge Right Cooling Fan error
|
When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Replace the Edge
Right Cooling Fan. 2. Replace the DC Controller Board.
|
0001H
|
Scanner Jam Code.
|
|
Non-DES sensors.
|
0002H
|
Scanner Jam Code.
|
|
DES Sensor Stationary
|
0004H
|
Printer Jam Code.
|
|
Re-pickup Delay Jam
|
0005H
|
Printer Jam Code.
|
|
Multi-purpose tray pickup delay jam.
|
0008H
|
Printer Jam Code.
|
|
Pickup Stationary Jam
|
000CH
|
Printer Jam Code.
|
|
Fixing Delivery Delay Jam
|
0010H
|
Printer Jam Code.
|
|
Fixing Delivery Stationary Jam
|
0014H
|
Printer Jam Code.
|
|
Internal Paper Jam
|
0018H
|
Printer Jam Code.
|
|
Door Open Jam
|
001CH
|
Printer Jam Code.
|
|
Wrap Jam
|
0020H
|
Reversal Delay Jam
|
|
0021H
|
Reversal Stationary Jam
|
0071H
|
Scanner Jam Code.
|
|
Timing error
|
0094H
|
Scanner Jam Code.
|
|
Initial Stationary
|
0095H
|
Scanner Jam Code.
|
|
Pickup NG
|