Код | Описание ошибки | Причины |
C0000 | Main Motor malfunction | The Main Motor (M1) Lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the Main Motor has started turning. |
C0044 | ADF Cooling Fan Failure (Only when the optional AFR-19 is mounted) | Refer to the option service manual (AFR-19) for details. |
C0045 | Fusing Cooling Fan Motor malfunction | The Fusing Cooling Fan Motor (M3) Lock signal HIGH for a continuous 1 -sec. period while the Fusing Cooling Fan Motor is turning at full speed or decelerated speed. |
C004E | Power Supply Cooling Fan Motor malfunction | The Power Supply Cooling Fan Motor (M4) Lock signal remains HIGH for a continuous 1-sec. period while the Power Supply Cooling Fan Motor Remote signal remains ON (for full-speed rotation) or OFF (for decelerated-speed rotation). |
C0070 | Toner Replenishing Motor malfunction | The Toner Bottle Home Position Sensor (PC7) outputs HIGH signal for a continuous 3.5-sec. period Toner Bottle is turning.The Toner Bottle Home Position Sensor (PC7) outputs a LOW signal for a continuous 2-sec. period while the Toner Bottle is turning. |
C0210 | Abnormal image transfer voltage | The image transfer voltage remains more than 100V continuously for a given period of time while the PC Drum remains stationary. |
C03FF | Faulty Model Setting | "Model Setting" of "Adjust" available from the Service mode is incorrectly set. |
С0500 | Warm-up failure | The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.
From room temperature to 100оС: | 35 sec. |
From 100оС to 140оС: | 25 sec. |
From 140оС to to the completion of the warm-up cycle: | 20 sec. |
|
С0500 | Warm-up failure (for the model having two Fusing Roller Heater Lamps) - Di2011 Only
| The Fusing Roller Thermistor does not detect a predetermined temperature within 30 sec. after a warm-up cycle has been started and thus the warm-up cycle is not completed. The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.
From room temperature to 60оС: | 4 sec. |
From 60оС to 100оС: | 2 sec. |
From 100оС to 130оС: | 1 sec. |
From 130оС to 150оС: | 0.5 sec. |
|
С0501 | Warm-up failure 2 (for the model having two Fusing Roller Heater Lamps) - Di2011 Only |
The Fusing Roller Sub Thermistor does not detect a predetermined temperature within 30 sec. after a warm-up cycle has been started and thus the warm-up cycle is not completed.
The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.
From room temperature to 60оС: | 7 sec. |
From 60оС to 100оС: | 2 sec. |
From 100оС to 130оС: | 1 sec. |
From 130оС to 150оС: | 0.5 sec. |
|
С0510 | Fusing failure (abnormally low fusing temperature) | The temperature detected by the Fusing Roller Thermistor remains lower than 120оС (105оС for the model having two Fusing Roller Heater Lamps) for a given period of time during the standby state.The temperature detected by the Fusing Roller Thermistor remains lower than 12OоС (105оС for the model having two Fusing Roller Heater Lamps) for a given period of time during a print cycle. |
C0511 | Fusing failure (abnormally low fusing temperature 2) - Di2011 Only | The temperature detected by the Fusing Roller Sub thermistor remains lower than 105оС for a given period of time during the standby state. The temperature detected by the Fusing Roller Subthermistor remains lower than 105оС for a given period of time during a print cycle. |
C0521 | Fusing failure (abnormally high fusing temperature 2) - Di2011 Only | The temperature detected by the Fusing Roller Sub Thermistor remains higher than 240°C for a given period of time. |
C0650 | Faulty Scanner Home Position Sensor | The Scanner Home Position Sensor (PC10) does not go from HIGH to LOW when the Scanner Motor M5 is energized for a given number of steps alter the sequence to bring the Scanner back to its home position has been started at the end of a scan motion and during re-shading. The Scanner Home Position Sensor (PC10) does not go from LOW to HIGH when the Scanner Motor M5 is energized for a given number of steps after a motion has been started at the end of a Scanner Position Sensor home check scan motion and during re-shading.
|
C0B60 | Bin Switching Motor malfunction (Only when the optional JS-204 is mounted) |
* Refer to the option service manual (JS-204) for details. |
C0B80 | Shift Motor malfunction (Only when the optional OT-103 is mounted) |
* Refer to the option service manual (OT-103) for details. |
C0F32 | Faulty ATDC Sensor | The measurement taken by the ATDC Senser (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is less than 5% (greater than 4.63 V). The measurement taken by the ATDC Senser (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is 19% or more (1.41 V or less).
|
C0F33 | Improperly adjusted ATDC sensor | The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment. The ATDC sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
|
C1038 | Engine connection failure | Master Board (PWB-A) to Control Board (PWB-C/C) connection failure There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more. An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A). An error status signal is transmitted from the Board (PWB-A) to Control Board (PWB-C/C).
|
C1200 | Faulty ASIC/memory | ASIC/memory (for image and control) fault A write or read error occurs with SRAM on the Board (PWB-C/C).
|
C1300 |
Polygon Motor malfunction |
Startup failure
A LOW Polygon Motor (M2) Lock signal is not detected within a given period of time that begins 1 sec after the Polygon Motor has started turning. |
Lock signal fault: Unstable after the first Lock signal has been detected For a period of 1 sec. after the first LOW Polygon Motor (M2) Lock signal (first Lock) has been detected, the LOW Polygon Motor Lock signal is not detected. |
Lock signal fault: Lock signal out-of-timing A LOW Polygon Motor (M2) Lock signal is not detected for a continuous given period of time while the rptation of the Polygon Motor remains stabilized. |
Faulty Lock signal A LOW Polygon Motor (M2) Lock signa is detected for a given period of time or more when the Polygon Motor remains deenergized. |
C133B | Communication with option error | It is not possible to communicate with the Printer Board within a predetermined period of time during a print cycle.
|
C133D | ROM check error | An error is detected of the flash ROM chip on the fax Board when the Power Switch is turned ON.
|
C13F0 | Faulty HSYNC | Laser scanning system malfunction The SOS Sensor does not detect a rising edge SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON.
|
C1468 | Faulty EEPROM | Data canot be written in EEPROM. Data stored in EEPROM is wrong.
|
C14A3 | IR Fluorescent lamp fault | The Exposure Lamp (LA2) of The Scanner fails to turn ON. The intensity of the Exposure Lamp (LA2) is predetermined value or less during shading and re-shading.
|