Код ошибки Неполадки Причина Устранение
0030 FAX control PWB system error Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. Replace the FAX control PWB .
0070 FAX control PWB incompatible detection Error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. Defective fax software. Install the fax software.
Defective FAX control PWB. Replace the FAX control PWB
0100 Backup memory device error Defective flash memory. Replace the control PWB 
Defective control PWB. Replace the control PWB 
0120 MAC address data error Defective flash memory. Replace the control PWB 
0130 Backup memory read/write error Defective flash memory. Replace the control PWB 
Defective control PWB. Replace the control PWB 
0140 Backup memory data error Defective flash memory. Replace the control PWB 
Defective control PWB. Replace the control PWB 
0150 Control PWB EEPROM error Detecting control PWB EEPROM (U17) communication error. Improper installation control PWB EEPROM (U17). Check the installation of the EEPROM (U17) and remedy if necessary 
Defective control PWB. Replace the control PWB
Data damage of control PWB EEPROM (U17). Contact the Service Administrative Division.
0170 Billing counting error Defective control PWB. Replace the control PWB 
Data damage of control PWB EEPROM (U17). Contact the Service Administrative Division.
0180 Machine number mismatch Machine number of main and engine does not match. The main PWB or the engine PWB were exchanged. U004 Setting the machine number 
Data damage of control PWB EEPROM (U17). Contact the Service Administrative Division.
0420 Paper feeder communication error Communication error between control PWB and optional paper feeder. Improper installation paper feeder. Follow installation instruction carefully again.
Defective harness between control PWB (YC30) and paper feeder interface connector, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective control PWB. Replace the control PWB 
Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
Defective PF mainPWB. Replace the PF main PWB (Refer to the service manual for the paper feeder)
0830 FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB. Defective fax software. Install the fax software.
Defective FAX control PWB. Replace the FAX control PWB 
0840 Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. Defective control PWB. Replace the control PWB 
The battery is disconnected from the control PWB. Check visually and remedy if necessary.
0870 FAX control PWB to control PWB high capacity data transfer problem High-capacity data transfer between the FAX control PWB and the control PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Reinstall the FAX control PWB
Defective FAX control PWB or control PWB. Replace the FAX control PWB or control PWB and check for correct operation.
0920 Fax file system error The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. Replace the FAX control PWB 
2000 Main motor error The main motor ready input is not given for 2 s during the main motor is ON. Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness 
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor 
Defective control PWB. Replace the control PWB 
2610 PF paper feed motor error (paper feeder) The PF paper feed motor of cassette 2 ready input is not given for 2 s during the PF paper feed motor is ON. Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
Defective PF paper feed motor drive transmission system. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective PF main motor. Replace the PF main motor.
Defective control PWB. Replace the control PWB 
2620 PF paper feed motor error (Paper feeder) The PF paper feed motor of cassette 3 ready input is not given for 2 s during the PF paper feed motor is ON. Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
    Defective PF paper feed motor drive transmission system. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective PF main motor. Replace the PF main motor (Refer to the service manual for the paper feeder).
    Defective control PWB. Replace the control PWB 
3100 ISU home position error Defective FFC between CCD PWB (YC1) and control PWB (YC8). Replace the image scanner unit (ISU)
    Defective FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC insertion. Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC.
    Defective home position sensor. Replace the home position sensor.
    Defective harness between ISU motor and scanner PWB (YC104), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective ISU motor. Replace the ISU motor.
3200 Exposure lamp error The exposure lamp is not turned on.  Defective FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC insertion. Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC.
    Defective FFC between CCD PWB (YC1) and control PWB (YC8). Replace the image scanner unit (ISU) 
    Defective harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective harness between LED drive PWB (YC2) and exposure lamp, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective exposure lamp. Replace the exposure lamp 
    Defective LED drive PWB. Replace the LED drive PWB 
    Defective control PWB. Replace the control PWB 
3300 AGC error After AGC, correct input is not obtained at CCD. Defective FFC between CCD PWB (YC1) and control PWB (YC8). Replace the image scanner unit (ISU) 
    Defective exposure lamp. Replace the exposure lamp 
    Defective CCD PWB. Replace the CCD PWB.
    Defective control PWB. Replace the control PWB 
3500 CPU - ASIC (CCD PWB) communication error An error code is detected. Defective FFC between CCD PWB (YC1) and control PWB (YC8). Replace the image scanner unit (ISU) 
    Defective CCD PWB. Replace the CCD PWB.
    Defective control PWB. Replace the control PWB 
4000 Polygon motor (laser scanner unit) error The polygon motor ready input is not given for 6 s during the polygon motor is ON. Defective harness between polygon motor and control PWB (YC10), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective laser scanner unit. Replace the laser scanner unit 
    Defective control PWB. Replace the control PWB 
4200 BD error (laser scanner unit) error BD sensor does not detect laser beam due to condensation on the polygon mirror. Turn machine power off for at least 30 minutes, then turn machine on again. If not cured, replace the laser scanner unit 
    Defective laser scanner unit. Replace the laser scanner unit 
    Defective control PWB. Replace the control PWB 
6000 Broken Fuser heater wire The fuser temperature does not rise after the Fuser heater has been turned on. Poor contact in the fuser thermistor connector terminals. Reinsert the connector 
    Poor contact in the Fuser heater connector terminals. Reinsert the connector 
    Fuser thermistor installed incorrectly. Replace the fuser unit 
    Fuser thermal cutout triggered. Replace the fuser unit 
    Fuser heater installed incorrectly. Replace the fuser unit 
    Broken Fuser heater wire. Replace the fuser unit
6020 Abnormally high fuser thermistor temperature Shorted fuser thermistor. Replace the fuser unit 
  Fuser thermistor detects abnormally temperature. Defective control PWB. Replace the control PWB 
6030 Broken fuser thermistor wire Input from fuser thermistor is 0 (A/D value). Poor contact in the fuser thermistor connector terminals. Reinsert the connector 
    Broken fuser thermistor wire. Replace the fuser unit 
    Fuser thermistor installed incorrectly. Replace the fuser unit 
    Fuser thermal cutout triggered. Replace the fuser unit 
    Fuser heater installed incorrectly. Replace the fuser unit
    Broken Fuser heater wire. Replace the fuser unit 
6400 Zero cross signal error The zero cross signal does not reach the control PWB for specified time. Defective harness between high voltage PWB (YC202) and control PWB (YC23), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness 
    Defective connection between power source PWB (YC103) and high voltage PWB (YC201). Reinsert the connector.
    Defective power source PWB. Replace the power source PWB 
    Defective control PWB. Replace the control PWB 
7990 Waste toner full The waste toner sensor has detected that the waste toner reservoir (drum unit) is full. Waste toner reservoir (drum unit) is full. Turn the power switch off/on to restart the machine. If the error is not resolved, replace the drum unit 
    Defective waste toner sensor. Replace the waste toner sensor.
    Defective control PWB. Replace the control PWB 
F000 Control PWB - Operation panel PWB communication error Defective harness between operation panel PWB (YC1) and control PWB (YC7), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective operation panel PWB. Replace the operation panel PWB.
    Defective control PWB. Replace the control PWB 
F020 Control PWB RAM checksum error Defective main memory (RAM) on the control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB 
    Defective expanded memory (DIMM). Replace the expanded memory (DIMM).
F040 Control PWB engine communication error A communication error is detected. Defective control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB 
F041 Control PWB - scanner PWB communication error A communication error is detected. Defective control PWB or scanner PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB or scanner PWB 
F050 Control PWB engine checksum error Some error may have occurred when downloading the firmware of the control PWB. Download the firmware of the control PWB again 
    Defective control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB 
F186 Control PWB video data control error Defective control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB 

Ошибка, код ошибки: C0030, C0070, C0100, C0120, C0130, C0140, C0150, C0170, C0180, C0420, C0830, C0840, C0870, C0920,
C2000, C2610, C2620, C3100, C3200, C3300, C3500, C4000, C4200, C6000, C6020, C6030, C6400, C7990, CF000,
CF020, CF040, CF041, CF050, CF186. Kyocera FS-1030 MFP, FS-1035 MFP, FS-1130 MFP, FS-1135 MFP



Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация