Коды ошибок Kyocera FS-1030MFP, 1035MFP, 1130MFP, 1135MFP |
|
Код
ошибки |
Неполадки |
Причина |
Устранение |
0030 |
FAX
control PWB system error Processing with the fax software
was disabled due to a hardware problem. |
Defective
FAX control PWB. |
Replace
the FAX control PWB . |
0070 |
FAX control PWB incompatible detection Error Abnormal detection of FAX control PWB incompatibility In the
initial communication with the FAX control PWB, any normal communication
command is not transmitted. |
Defective
fax software. |
Install the fax
software. |
Defective FAX control PWB. |
Replace
the FAX control PWB |
0100 |
Backup memory device error |
Defective
flash memory. |
Replace the control PWB |
Defective control PWB. |
Replace the control PWB |
0120 |
MAC address data
error |
Defective
flash memory. |
Replace the control PWB |
0130 |
Backup memory read/write error |
Defective
flash memory. |
Replace the control PWB |
Defective control PWB. |
Replace the control PWB |
0140 |
Backup memory data error |
Defective
flash memory. |
Replace the control PWB |
Defective control PWB. |
Replace the control PWB |
0150 |
Control PWB EEPROM error Detecting
control PWB EEPROM (U17) communication error. |
Improper
installation control PWB EEPROM (U17). |
Check
the installation of the EEPROM (U17) and remedy if necessary |
Defective control PWB. |
Replace
the control PWB |
Data damage of control PWB EEPROM (U17). |
Contact
the Service Administrative Division. |
0170 |
Billing counting error |
Defective
control PWB. |
Replace the control PWB |
Data damage of control PWB EEPROM (U17). |
Contact
the Service Administrative Division. |
0180 |
Machine number mismatch Machine
number of main and engine does not match. |
The
main PWB or the engine PWB were exchanged. |
U004 Setting the machine number |
Data damage of control PWB EEPROM (U17). |
Contact
the Service Administrative Division. |
0420 |
Paper feeder communication error Communication error between control PWB and optional paper
feeder. |
Improper
installation paper feeder. |
Follow
installation instruction carefully again. |
Defective harness between control PWB (YC30)
and paper feeder interface connector, or improper connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
Defective control PWB. |
Replace the control PWB |
Defective harness between PF main PWB (YC5) and
paper feeder interface connector, or improper connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness (Refer to the service manual for the
paper feeder). |
Defective PF mainPWB. |
Replace
the PF main PWB (Refer to the service manual for the paper feeder) |
0830 |
FAX control PWB flash program area checksum
error A checksum error occurred with the program of the
FAX control PWB. |
Defective
fax software. |
Install the fax
software. |
Defective FAX control PWB. |
Replace the FAX control PWB |
0840 |
Faults of RTC The time is
judged to go back based on the comparison of the RTC time and the current
time or five years or more have passed. |
Defective
control PWB. |
Replace the control PWB |
The battery is disconnected from the control
PWB. |
Check visually and
remedy if necessary. |
0870 |
FAX control PWB to control PWB high capacity
data transfer problem High-capacity data transfer between
the FAX control PWB and the control PWB of the machine was not normally
performed even if the data transfer was retried the specified times. |
Improper
installation FAX control PWB. |
Reinstall
the FAX control PWB |
Defective FAX control PWB or control PWB. |
Replace
the FAX control PWB or control PWB and check for correct operation. |
0920 |
Fax
file system error The backup data is not retained for
file system abnormality of flash memory of the FAX control PWB. |
Defective
FAX control PWB. |
Replace the FAX control PWB |
2000 |
Main motor error The main
motor ready input is not given for 2 s during the main motor is ON. |
Defective
harness between main motor (CN1) and control PWB (YC17), or improper
connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness |
Defective drive transmission system of the main
motor. |
Check
if the rollers and gears rotate smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if any. |
Defective main motor. |
Replace the main motor |
Defective control PWB. |
Replace the control PWB |
2610 |
PF paper feed motor error (paper feeder) The PF paper feed motor of cassette 2 ready input is not given
for 2 s during the PF paper feed motor is ON. |
Defective
harness between PF paper feed motor and PF main PWB (YC4), or improper
connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness (Refer to the service manual for the
paper feeder). |
Defective PF paper feed motor drive
transmission system. |
Check
if the gears rotate smoothly. If not, grease the bushings and gears. Check
for broken gears and replace if any. |
Defective PF main motor. |
Replace the PF main
motor. |
Defective control PWB. |
Replace the control PWB |
2620 |
PF
paper feed motor error (Paper feeder) The PF paper feed
motor of cassette 3 ready input is not given for 2 s during the PF paper feed
motor is ON. |
Defective
harness between PF paper feed motor and PF main PWB (YC4), or improper
connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness (Refer to the service manual for the
paper feeder). |
|
|
Defective
PF paper feed motor drive transmission system. |
Check
if the gears rotate smoothly. If not, grease the bushings and gears. Check
for broken gears and replace if any. |
|
|
Defective
PF main motor. |
Replace
the PF main motor (Refer to the service manual for the paper feeder). |
|
|
Defective
control PWB. |
Replace the control PWB |
3100 |
ISU home position
error |
Defective
FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace
the image scanner unit (ISU) |
|
|
Defective
FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC
insertion. |
Reinsert
the FFC. Also check for continuity within the FFC. If none, remedy or replace
the FFC. |
|
|
Defective
home position sensor. |
Replace the home
position sensor. |
|
|
Defective
harness between ISU motor and scanner PWB (YC104), or improper connector
insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
|
|
Defective
ISU motor. |
Replace the ISU
motor. |
3200 |
Exposure
lamp error The exposure lamp is not turned on. |
Defective
FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC
insertion. |
Reinsert
the FFC. Also check for continuity within the FFC. If none, remedy or replace
the FFC. |
|
|
Defective
FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit
(ISU) |
|
|
Defective
harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector
insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
|
|
Defective
harness between LED drive PWB (YC2) and exposure lamp, or improper connector
insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
|
|
Defective
exposure lamp. |
Replace the exposure lamp |
|
|
Defective
LED drive PWB. |
Replace the LED drive PWB |
|
|
Defective
control PWB. |
Replace the control PWB |
3300 |
AGC
error After AGC, correct input is not obtained at CCD. |
Defective
FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit
(ISU) |
|
|
Defective
exposure lamp. |
Replace the exposure lamp |
|
|
Defective
CCD PWB. |
Replace the CCD PWB. |
|
|
Defective
control PWB. |
Replace the control PWB |
3500 |
CPU
- ASIC (CCD PWB) communication error An error code is
detected. |
Defective
FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit
(ISU) |
|
|
Defective
CCD PWB. |
Replace the CCD PWB. |
|
|
Defective
control PWB. |
Replace the control PWB |
4000 |
Polygon
motor (laser scanner unit) error The polygon motor ready
input is not given for 6 s during the polygon motor is ON. |
Defective
harness between polygon motor and control PWB (YC10), or improper connector
insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
|
|
Defective
laser scanner unit. |
Replace the laser scanner unit |
|
|
Defective
control PWB. |
Replace the control PWB |
4200 |
BD error (laser
scanner unit) error |
BD
sensor does not detect laser beam due to condensation on the polygon mirror. |
Turn
machine power off for at least 30 minutes, then turn machine on again. If not
cured, replace the laser scanner unit |
|
|
Defective
laser scanner unit. |
Replace the laser scanner unit |
|
|
Defective
control PWB. |
Replace the control PWB |
6000 |
Broken
Fuser heater wire The fuser temperature does not rise
after the Fuser heater has been turned on. |
Poor
contact in the fuser thermistor connector terminals. |
Reinsert the connector |
|
|
Poor
contact in the Fuser heater connector terminals. |
Reinsert the connector |
|
|
Fuser
thermistor installed incorrectly. |
Replace the fuser unit |
|
|
Fuser
thermal cutout triggered. |
Replace the fuser unit |
|
|
Fuser
heater installed incorrectly. |
Replace the fuser unit |
|
|
Broken
Fuser heater wire. |
Replace
the fuser unit |
6020 |
Abnormally
high fuser thermistor temperature |
Shorted
fuser thermistor. |
Replace the fuser unit |
|
Fuser
thermistor detects abnormally temperature. |
Defective
control PWB. |
Replace the control PWB |
6030 |
Broken
fuser thermistor wire Input from fuser thermistor is 0
(A/D value). |
Poor
contact in the fuser thermistor connector terminals. |
Reinsert the connector |
|
|
Broken
fuser thermistor wire. |
Replace the fuser unit |
|
|
Fuser
thermistor installed incorrectly. |
Replace the fuser unit |
|
|
Fuser
thermal cutout triggered. |
Replace the fuser unit |
|
|
Fuser
heater installed incorrectly. |
Replace
the fuser unit |
|
|
Broken
Fuser heater wire. |
Replace the fuser unit |
6400 |
Zero
cross signal error The zero cross signal does not reach
the control PWB for specified time. |
Defective
harness between high voltage PWB (YC202) and control PWB (YC23), or improper
connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness |
|
|
Defective
connection between power source PWB (YC103) and high voltage PWB (YC201). |
Reinsert the
connector. |
|
|
Defective
power source PWB. |
Replace the power source PWB |
|
|
Defective
control PWB. |
Replace the control PWB |
7990 |
Waste
toner full The waste toner sensor has detected that the
waste toner reservoir (drum unit) is full. |
Waste
toner reservoir (drum unit) is full. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace the drum unit |
|
|
Defective
waste toner sensor. |
Replace the waste
toner sensor. |
|
|
Defective
control PWB. |
Replace the control PWB |
F000 |
Control
PWB - Operation panel PWB communication error |
Defective
harness between operation panel PWB (YC1) and control PWB (YC7), or improper
connector insertion. |
Reinsert
the connector. Also check for continuity within the connector harness. If
none, remedy or replace the harness. |
|
|
Defective
operation panel PWB. |
Replace the operation
panel PWB. |
|
|
Defective
control PWB. |
Replace the control PWB |
F020 |
Control
PWB RAM checksum error |
Defective
main memory (RAM) on the control PWB. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace control PWB |
|
|
Defective
expanded memory (DIMM). |
Replace
the expanded memory (DIMM). |
F040 |
Control
PWB engine communication error A communication error is
detected. |
Defective
control PWB. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace control PWB |
F041 |
Control
PWB - scanner PWB communication error A communication
error is detected. |
Defective
control PWB or scanner PWB. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace control PWB or scanner PWB |
F050 |
Control
PWB engine checksum error |
Some
error may have occurred when downloading the firmware of the control PWB. |
Download the firmware
of the control PWB again |
|
|
Defective
control PWB. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace control PWB |
F186 |
Control
PWB video data control error |
Defective
control PWB. |
Turn
the power switch off/on to restart the machine. If the error is not resolved,
replace control PWB |
|
|
|
|
|
|
|