ОргТехСервис
Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Коды ошибок Kyocera ECOSYS m2735dw, сброс

  • Code: 0030
  • Description: FAX PWB system error The FAX process cannot be continued due to the malfunction of the FAX PWB.
  • Remedy: FAX PWB Replace the FAX PWB
  • Code: 0070
  • Description: FAX PWB incompatible detection error In the initial communication with the FAX PWB,
  • Remedy: FAX PWB Replace the FAX PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 0100
  • Description: Backup memory device error Outputs an abnormal status from the flash memory.
  • Remedy: Flash memory Replace the main/engine PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 0120
  • Description: MAC address data error In case MAC address is invalid data
  • Remedy: Flash memory Replace the main/engine PWB.
  • Code: 0130
  • Description: Backup memory Read/write error Read/write to the NAND memory cannot be executed.
  • Remedy: Flash memory Replace the main/engine PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 0140
  • Description: Backup memory data error At power up, the data that was read from the NAND memory has been determined to be a error.
  • Remedy: Flash memory Replace the main/engine PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 0150
  • Description: EEPROM read/write error (Main/ Engine PWB) Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: EEPROM(YS1) Confirm that the EEPROM has been properly installed and repair if failed. Main/Engine PWB Replace the main/engine PWB. EEPROM(YS1) Contact the service support.
  • Code: 0160
  • Description: Backup memory data error Illegal data is detected in the EEPROM Counter data checksum does not match in all buffers
  • Remedy: EEPROM(YS1) Check that the EEPROM (YS1) is firmly installed and repair it if failed. Main/Engine PWB Replace the main/engine PWB. EEPROM(YS1) Contact the service support.
  • Code: 0170
  • Description: Billing counting error Checksum error was detected both in the billing counter and IPU backup memory
  • Remedy: Main/Engine PWB Replace the main/engine PWB.
  • Code: 0180
  • Description: Machine number mismatch When the power is turned on, the machine number does not match between the main and engine side.
  • Remedy: Main/Engine PWB Execute U004 machine number setting EEPROM(YS1) Contact the service support.
  • Code: 0190
  • Description: Backup memory device error Unable to read out data from the EEPROM. The above remains at 3 times of retries
  • Remedy: Main/Engine PWB Replace the main/engine PWB. EEPROM(YS1) Contact the service support.
  • Code: 0500
  • Description: Drive lock detection by engine firmware The main motor was left rotating when monitoring it in the regular interval (monitored also during the maintenance mode)
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: 0510
  • Description: High voltage remote control error detection It was detected that the high voltage remote signal (synchronized with the feed motor remote) is on while the drum is not driven
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: 0530
  • Description: Backup task error detection The time for the backup task not being in operation is 30s or more
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: 0540
  • Description: Unexpected engine firmware control detection? (Preventing the solenoid from continuously being on) The solenoid was continuously on for the specified time or more
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: 0800
  • Description: Print sequence error The printing sequence jam (JAM010X) occurred twice consecutively.
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: 0830
  • Description: FAX PWB flash program area checksum error The program stored in the flash memory on the FAX PWB is broken and cannot be executed.
  • Remedy: FAX PWB Replace the FAX PWB.
  • Code: 0840
  • Description: RTC error Communication with the RTC has failed The RTC data mismatch such as dead battery
  • Remedy: Battery on the main/engine PWB Check it and repair it if it is faulty. Main/Engine PWB Replace the main/engine PWB.
  • Code: 0870
  • Description: FAX PWB large data transmission error DMA transmission failed between the main/engine PWB and FAX PWB
  • Remedy: FAX PWB Reattach the FAX PWB. FAX PWB or main/engine PWB Replace the FAX PWB or main/engine PWB.
  • Code: 0920
  • Description: Fax file system error The backup data is not retained for file system abnormality of the flash memory of the FAX PWB.
  • Remedy: FAX PWB Replace the FAX PWB.
  • Code: 0970
  • Description: 24V power down detect The power shutoff was detected by the controller
  • Remedy: Interlock switch Check that the interlock switch is turned on properly by the front cove. Low voltage power supply PWB Check if there is defective connection in the connector of the low voltage power supply PWB, and then check the 24V output from the main/engine PWB (YC20-1, 2,3). If not, replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB and check the operation.
  • Code: 1810
  • Description: Communication error with the paper feeder (1st PF) No paper feeder was detected after the paper feeder connection was detected at power-up
  • Remedy: Paper feeder Check the wiring connection status with the main unit, and if necessary, reconnect it. PF main PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. PF main PWB - Main/engine PWB (YC17) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the PF main PWB. Main/ Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 1820
  • Description: Communication error with the paper feeder (2nd PF) No paper feeder was detected after the paper feeder connection was detected at power-up
  • Remedy: Paper feeder Check the wiring connection status with the main unit, and if necessary, reconnect it. PF main PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. PF main PWB and Main/engine PWB (YC47) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the PF main PWB. Main/ Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 2000
  • Description: Main motor steady-state error After the main motor was stabilized, the ready signal was not detected for consecutive 1s.
  • Remedy: Wire and connector between the main motor and main/engine PWB (YC9) If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity. Main motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage. Main motor Replace the main motor. Main/Engine PWB Replace the main/engine PWB.
  • Code: 2010
  • Description: Main motor start-up error The ready signal was not detected when passing 2s after the main motor is started up.
  • Remedy: Wire and connector between the main motor and main/engine PWB (YC9) If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity. Main motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage. Main motor Replace the main motor. Main/Engine PWB Replace the main/engine PWB.
  • Code: 2600
  • Description: PF conveying motor error (Paper feeder) The ready signal is not detected within 2s after the PF conveying motor of the cassette 2 turns on.
  • Remedy: Connection of the wire and connector PF conveying motor - PF main PWB If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity. PF conveying motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage. PF conveying motor Replace the PF conveying motor.
  • Code: 2610
  • Description: PF conveying motor error (Paper feeder) The ready signal is not detected within 2s after the PF conveying motor of the cassette 3 turns on.
  • Remedy: Connection of the wire and connector PF conveying motor - PF main PWB If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity. PF conveying motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage. PF conveying motor Replace the PF conveying motor.
  • Code: 3100
  • Description: Carriage error 1) While the HP sensor is interrupted at the initial drive, it is not released when driven by 66.1mm toward the scanning direction 2) During the initial drive while the HP sensor is released, the HP sensor is not interrupted when driving it by 379.5mm toward the return direction
  • Remedy: Scanner motor 1. Move the scanner manually to check if there is too much load. 2. Check that the scanner drive belt is not disengaged. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Scanner motor - Main/engine PWB (YC31) 4. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 5. Replace the scanner motor. Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected, Insert the connector all the way in. Home position sensor - Main/engine PWB (YC17) 3. Replace the home position sensor. CIS Replace the scanner carriage and execute U411. Main/ Engine PWB Replace the main/engine PWB.
  • Code: 3200
  • Description: CIS lamp error The white reference data obtained when the lamp is turned on at the time of initialization is lower than the rated value.
  • Remedy: CIS Replace the scanner carriage and execute U411. Main/ Engine PWB Replace the main/engine PWB.
  • Code: 3210
  • Description: DP CIS lamp error The white reference data obtained when the lamp is turned on at the time of initialization is lower than the rated value. (40 ppm model only)
  • Remedy: DP CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPCIS - Main/Engine PWB(YC509) 2. Replace DPCIS and execute U411.
  • Code: 3300
  • Description: CIS AGC error An error was detected when processing the front side AGC
  • Remedy: CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS - Main/Engine PWB (YC506) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the scanner carriage and execute U411 Main/Engine PWB Replace the main/engine PWB.
  • Code: 3310
  • Description: DP CIS AGC error An error was detected when processing the back side AGC (40 ppm model only)
  • Remedy: DP CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPCIS - Main/Engine PWB(YC509) 2. Replace DPCIS and execute U411. Main/Engine PWB Replace the main/engine PWB.
  • Code: 3500
  • Description: Scanner - ASIC communication error A communication error is detected during communication. (Read-back values are different.)
  • Remedy: CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS - Main/Engine PWB (YC506) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the image scanner carriage and execute U411. Main/Engine PWB Replace the main/engine PWB.
  • Code: 4000
  • Description: Polygon motor initial error (LSU) The polygon motor ready signal is not detected when passing 10s after starting up the polygon motor
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Polygon motor - Main/engine PWB (YC3) If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 2. Replace the LSU. Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 4010
  • Description: Polygon motor steady-state error (LSU) The polygon motor ready signal is not for consecutive 1s after the polygon motor is stabilized
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Polygon motor - Main/engine PWB (YC3) If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 2. Replace the LSU. Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 4201
  • Description: BD steady-state error (LSU) BD was not obtained during the steady rotation
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU - Main/Engine PWB (YC505) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the LSU. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6000
  • Description: Broken fuser heater wire (main) During warm-up, the temperature detected by the thermopile does not reach 100°C/212 °F when turning the heater on for consecutive 10s During warm up, the temperature detected by the thermopile does not reach the ready temperature when passing 30s after reaching 60°C/ 212°F.
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Heater - Low voltage power supply PWB (YC102) Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6020
  • Description: Fuser thermopile high temperature error (main) During drive, the thermopile detected 200C/392 °F for 5s The temperature detected by the thermopile rose 18C/65 °F or more when passing 1s or more after the drive is stopped Detected temperature at that time is 200C/392 °or more
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Check how the thermopile is attached. If not attached to the holder, correct it 3. Replace the thermopile if not repaired Fuser unit 1. Make sure there is no paper jam. 2. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6030
  • Description: Broken fuser thermopile wire (main) The thermopile detected an abnormal value
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Replace the thermopile if not repaired Main/Engine PWB Replace the main/engine PWB.
  • Code: 6050
  • Description: Fuser thermopile low temperature error (main) During printing, the temperature detected by the thermopile is less than 100C/212°F for consecutive 3s
  • Remedy: Power supply voltage 1. Check no voltage drop exceeding 10% of the rated during printing. 2. If the power is overloaded, change the AC outlet that supplies power. Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Check how the thermopile is attached. If not attached to the holder, correct it 3. Replace the thermopile if not repaired Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Heater - Low voltage power supply PWB (YC102) Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6200
  • Description: Fuser heater error (sub) During warm-up, the temperature detected by the thermistor does not reach 60C/212.0 °F when turning the heater on for consecutive 30s. During warm-up, the temperature detected by the thermistor does not reach the ready temperature when passing 20s after it reaches 60C/ 212°F.
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Replace the thermopile if not repaired Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Heater - Low voltage power supply PWB (YC102) Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6220
  • Description: Fuser heater high temperature error (sub) The temperature detected by the thermopile is 240°C/464 °F while the drive is stopped The temperature detected by the thermopile is 255°C/491 °F during drive
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Check how the thermopile is attached. If not attached to the holder, correct it 3. Replace the thermopile if not repaired Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. Replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6230
  • Description: Fuser thermistor wire break (sub) The thermistor's AD value was abnormal
  • Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6250
  • Description: Fuser heater low temperature error (sub) During printing, the temperature detected by the thermistor is less than 60°C/140°F for consecutive 3s
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. Thermopile - Main/engine PWB (YC2) 2. Check how the thermopile is attached. If not attached to the holder, correct it 3. Replace the thermopile if not repaired Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. Replace the fuser unit. Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Heater - Low voltage power supply PWB (YC102) Low voltage power supply PWB - Main/ Engine PWB(YC20) 2. Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6400
  • Description: Zero-cross signal error During the heater turned on, the zero-cross signal disappears for consecutive 1s
  • Remedy: Low voltage power supply PWB Replace the low voltage power supply PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6600
  • Description: Fuser rotation error The fuser roller rotation detection is not input for consecutive 2s while the motor's steady signal is input
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/Engine PWB(YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. Replace the fuser unit. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6610
  • Description: The fuser pressure release error The fuser pressure change is not complete within 10s after the instruction
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit - Main/engine PWB (YC19) 3. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 4. Replace the fuser unit. Fuser pressure release error 1. Reverse-rotate the fuser gear manually to check if the fuser pressure can be released. 2. When releasing the pressure, check the fuser pressure release sensor is interrupted by the actuator Reattach it if the light is not interrupted 3. Reconnect the wire connector Replace the wire if there is no continuity. Fuser pressure release sensor - Main/ engine PWB (YC19) Fuser pressure release motor - Main/ engine PWB (YC1) 4. Replace the fuser pressure release motor. Main/Engine PWB Replace the main/engine PWB.
  • Code: 6650
  • Description: Fuser thermopile EEPROM error 1. The thermopile EEPROM is not accessed 2. No response from the device at read was detected five time consecutively Data read at two points was unmatched eight times consecutively 3. Thermopile data checksum error
  • Remedy: Thermopile 1. Reconnect the wire connector Replace the wire if there is no continuity. 2. Thermopile - Main/engine PWB (YC2) 3. Replace the thermopile if not repaired Main/Engine PWB Replace the main/engine PWB.
  • Code: 7220
  • Description: Broken in-machine thermistor wire The sensor input sampling value is greater than the reference value.
  • Remedy: In-machine temperature sensor 1. Confirm that the wiring connector is firmly connected, Insert the connector all the way in. In-machine temperature sensor - Main/engine PWB (YC1) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. Replace the in-machine temperature sensor PWB. Main/Engine PWB Replace the main/engine PWB.
  • Code: 7800
  • Description: Broken outer thermistor wire The sensor input sampling value is abnormal. (After detecting an error, it is controlled at 23C/77 °F and 50%RH)
  • Remedy: Temperature and humidity Sensor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Temperature and humidity sensor - Main/engine PWB (YC2) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the Temperature and humidity sensor PWB.
  • Code: 7990
  • Description: Waste toner full The waste toner sensor detected the waste toner reservoir in the drum unit is full
  • Remedy: Drum unit Turn the power switch off and on Replace the drum unit if not repaired. Waste toner sensor Replace the waste toner sensor. Main/Engine PWB Replace the main/engine PWB.
  • Code: F000
  • Description: Communication error between Main/Engine PWB - Operation panel PWB
  • Remedy: Connection of the wires and connectors between the main/engine PWB - the operation panel PWB. If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity. Operation panel PWB Replace the operation panel PWB. (TSI: see page 4-138, LCD: see page 4- 141) Main/Engine PWB Replace the main/engine PWB.
  • Code: F010
  • Description: Main/Engine PWB Checksum error
  • Remedy: Main/Engine PWB Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. If not corrected, replace the main/ engine PWB.
  • Code: F020
  • Description: Main/engine PWB RAM checksum error
  • Remedy: Main/engine PWB memory (RAM) Turn the power switch off and on If not corrected, replace the main/ engine PWB. Expansion memory (DIMM) Replace the expansion memory (DIMM)
  • Code: F040
  • Description: Main/engine PWB engine communication error
  • Remedy: Main/Engine PWB Turn the power switch off and on If not repaired, replace the EEPROM on the main/engine PWB or main/engine PWB.
  • Code: F041
  • Description: Main/engine PWB - Scanner PWB communication error
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
  • Code: F050
  • Description: Main/engine PWB engine checksum error
  • Remedy: Main/Engine PWB Download the engine firmware again (TSI: see page 4-138,LCD: see page 4- 141) Main/Engine PWB Turn the power switch off and on If not repaired, replace the EEPROM on the main/engine PWB or main/engine PWB.
  • Code: F051
  • Description: No scan engine main program
  • Remedy: Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.


Kyocera m2735dw ошибка 7990, C7990, 6000, C6000, 6020, C6020, 6030, C6030, 6050, C6050, 6200, C6200, 6230, C6230, 6250, C6250 сброс ошибки



Коды ошибок Kyocera ecosys m2735dw, 2735, kyocera m2735dw ошибка, kyocera 2735 ошибка, коды ошибок kyocera m2735dw, сброс ошибки, 7990, C7990, код ошибки, как сбросить ошибку, сброс
kyocera m2735dw как сбросить ошибку, kyocera m2735 ошибка, kyocera m2735dw ошибка C7990, kyocera 2735 ошибка, сброс, ECOSYS 2735 код ошибки, сброс, Коды ошибок Kyocera Ecosys 2735, kyocera 2735 ошибка С0030, С0070, С0100, С0120, С0130, С0140, С0150, С0160, С0170, С0180, С0190, С0500, С0510, С0530, С0540, С0800, С0830, С0840, С0870, С0920, С0970, С1810, С1820, С2000, С2010, С2600, С2610, С3100, С3200, С3210, С3300, С3310, С3500, С4000, С4010, С4201, С6000, С6020, С6030, С6050, С6200, С6220, С6230, С6250, С6400, С6600, С6610, С6650, С7220, С7800, С7990 C0030, C0070, C0100, C0120, C0130, C0140, C0150, C0160, C0170, C0180, C0190, C0500, C0510, C0530, C0540, C0800, C0830, C0840, C0870, C0920, C0970, C1810, C1820, C2000, C2010, C2600, C2610, C3100, C3200, C3210, C3300, C3310, C3500, C4000, C4010, C4201, C6000, C6020, C6030, C6050, C6200, C6220, C6230, C6250, C6400, C6600, C6610, C6650, C7220, C7800, C7990, CF000, CF010, CF020, CF040, CF041, CF050, CF051 0030, 0070, 0100, 0120, 0130, 0140, 0150, 0160, 0170, 0180, 0190, 0500, 0510, 0530, 0540, 0800, 0830, 0840, 0870, 0920, 0970, 1810, 1820, 2000, 2010, 2600, 2610, 3100, 3200, 3210, 3300, 3310, 3500, 4000, 4010, 4201, 6000, 6020, 6030, 6050, 6200, 6220, 6230, 6250, 6400, 6600, 6610, 6650, 7220, 7800, 7990, F000, F010, F020, F040, F041, F050, F051

Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Rambler's Top100 Рейтинг@Mail.ru