E000 Startup failure 1. Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
2. Replace the Fixing Assembly.
3. Replace the Engine Controller PCB.
E001 Abnormal high temperature 1. Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
2. Replace the Fixing Assembly.
3. Replace the Engine Controller PCB.
E003 Abnormal low temperature 1. Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
2. Replace the Fixing Assembly.
3. Replace the Engine Controller PCB.
E004 Fixing heater drive circuit error (200V models only) 1. Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
2. Replace the Fixing Assembly.
3. Replace the Engine Controller PCB.
E100 Scanner area failure 1. Check connectors on the scanner unit.
2. Replace the scanner unit
3. Replace the Engine Controller PCB.
E196 ROM read/write error (error in storing setting values in user mode/service mode/ factory mode) When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
1. Update the firmware of the Main Controller PCB.
2. Replace the Main Controller PCB.
E202 CIS Unit home position detection error / homeward reading position error When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
1. Check the connection between the Main Controller PCB and the CIS Unit. (J2)
2. Replace CIS Unit.
3. Check the connection between the Main Controller PCB and the Reader Motor (M3). (J11)
4. Replace the Reader Motor (M3).
5. Replace the Main Controller PCB.
E225 Insufficient lamp light intensity (The light intensity is at the reference level or below.) When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
1. Check the connection between the Main Controller PCB and the CIS Unit. (J2)
2. Replace CIS Unit.
3. Replace the Main Controller PCB.
E301 Insufficient light intensity at shading When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
1. Check the connection between the Main Controller PCB and the CIS Unit. (J2)
2. Replace CIS Unit.
3. Replace the Main Controller PCB.
E744 System error When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
1. Replace the Main Controller PCB.
2. Replace the Engine Controller PCB.


Canon MF 3010 ошибка

E000, E001, E003, E004, E100, E196, E202, E225, E301, E744

Canon 3010 cброс ошибки, как сбросить ошибку?

Canon 3010 ошибка E001, Canon 3010 ошибка E003, Canon 3010 ошибка E004, Canon 3010 ошибка E100, Canon 3010 ошибка E196, Canon 3010 ошибка E202, Canon 3010 ошибка E301, Canon 3010 ошибка E744.

Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация

Rambler's Top100 Рейтинг@Mail.ru