Код ошибки Неполадки Причина Устранение
0030 FAX control PWB system error Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. Replace the fax control PWB and check for correct operation. 
0070 FAX control PWB incompatible detection error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. Defective FAX software. Install the fax software.
Defective FAX control PWB. Replace the fax control PWB and check for correct operation. 
0100 Backup memory device error Defective flash memory. Replace the main PWB and check for correct operation 
Defective main PWB. Replace the main PWB and check for correct operation 
0120 MAC address data error For data in which the MAC address is invalid. Defective flash memory. Replace the main PWB and check for correct operation 
Defective engine PWB, Replace the engine PWB and check for correct operation 
0130 Backup memory read/ write error (main PWB) Defective flash memory. Replace the main PWB and check for correct operation 
Defective main PWB. Replace the main PWB and check for correct operation 
0140 Backup memory data error (main PWB) Defective flash memory. Replace the main PWB and check for correct operation 
Defective main , PWB. Replace the main PWB and check for correct operation 
0150 Engine PWB EEPROM error Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Check the installation of the EEPROM and remedy if necessary.
Defective engine PWB. Replace the engine PWB and check for correct operation 
Device damage of EEPROM. Contact the Service Administrative Division.
0170 Billing counting error A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Contact the Service Administrative Division.
Defective PWB. Replace the main PWB or the engine PWB and check for correct operation 
0180 Machine number mismatch Machine number of main and engine does not match. Data damage of EEPROM. Contact the Service Administrative Division.
0420 Paper feeder communication error Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Paper feeder interface and connect-L PWB (YC2) Connect-L PWB (YC6) and engine PWB (YC504)
Defective engine PWB. Replace the engine PWB and check for correct operation 
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
0830 FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Install the fax software.
Defective FAX control PWB. Replace the FAX control PWB 
0840 Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Check visually and remedy if necessary
Defective main PWB. Replace the main PWB and check for correct operation 
0870 FAX control PWB to main PWB high capacity data transfer error High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Reinstall the FAX control PWB 
Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation
0920 Fax file system error The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. Replace the FAX control PWB and check for correct operation 
1010 Lift motor error During driving the lift motor, a motor overcurrent signal is detected for 5 s. This error is detected five times successively. Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Lift motor and connect-R PWB (YC8) Connect-R PWB (YC2) and engine PWB (YC502)
Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective lift motor. Replace the lift motor
Defective engine PWB or connect-R PWB. Replace the engine PWB or connect-R PWB and check for correct operation
2000 Main motor steady-state error The main motor ready input is not given for 2 s during the main motor is ON. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Main motor and engine PWB (YC501)
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective engine PWB. Replace the engine PWB and check for correct operation
2200 Drum motor steady-state error The drum motor ready input is not given for 2 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Drum motor and engine PWB (YC11)
Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective drum motor. Replace the drum motor.
Defective engine PWB. Replace the engine PWB and check for correct operation 
3100 ISU home position error The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Home position sensor and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8) ISU motor and main PWB (YC1004)
    Defective home position sensor. Replace the home position sensor.
    Defective ISU motor. Replace the ISU motor.
    Defective CCD PWB. Replace the scanner unit 
    Defective main PWB. Replace the main PWB and check for correct operation 
3200 Exposure lamp error When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. LED PWB (YC1) and LED drive PWB (YC2) LED drive PWB (YC1) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8)
    Defective exposure lamp or LED drive PWB. Replace the scanner unit 
    Defective CCD PWB. Replace the scanner unit 
    Defective main PWB. Replace the main PWB and check for correct operation 
3300 AGC error After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Inverter PWB (YC101) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8)
    Defective exposure lamp or inverter PWB. Replace the scanner unit 
    Defective CCD PWB. Replace the scanner unit 
    Defective main PWB. Replace the main PWB and check for correct operation 
3500 Communication error between scanner and ASIC An error code is detected. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. CCD PWB (YC2) and main PWB (YC8)
Defective CCD PWB. Replace the scanner unit 
Defective main PWB. Replace the main PWB and check for correct operation (see page 1-5-34).
4000 Polygon motor synchronization error The polygon motor ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Laser scanner unit and main PWB (YC14)
Defective polygon motor. Replace the laser scanner unit 
Defective main PWB. Replace the main PWB and check for correct operation 
4200 BD steady-state error Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Laser scanner unit and main PWB (YC16)
Defective laser scanner unit. Replace the laser scanner unit (see page 1-5-16).
Defective main PWB. Replace the main PWB and check for correct operation 
4700 VIDEO ASIC device error Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main PWB (YC13) and engine PWB (YC12)
Defective main PWB or engine PWB. Replace the main PWB or the engine PWB and check for correct operation 
5100 Main charger high-volt-age error Five pages have been printed with the main charger output short-circuited. Drum unit installed incorrectly. Verify harness is not pinched.
Engine PWB installed incorrectly. Verify harness is not pinched.
Defective engine PWB. Replace the engine PWB and check for correct operation 
6000 Broken fuser heater wire The temperature does not reach 100°C/212°F after the fuser heater has been turned on continuously for Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Fuser heater and power source PWB (YC102) Fuser unit and engine PWB (YC506)
  30 s. The temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been Deformed connector pin. Fix it
  Defective triac.  
  turned on continuously for 15 s during warm-up or at standby.(Only when the detection temperature is less than 200°C.) Fuser thermostat triggered. Reinsert the fuser unit 
  Broken fuser heater wire. Replace the fuser unit 
6020 Abnormally high fuser thermistor 2 temperature Shorted fuser thermistor 2. Replace the fuser unit 
  The temperature of the fuser thermistor 2 detects 250°C/482°F or more continuously for 3 s. Deformed connector pin. Fix it
  Defective triac.  
    Defective engine PWB. Replace the engine PWB and check for correct operation 
6030 Broken fuser thermistor 2 wire average AD value input from fuser thermistor 2 for Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Fuser unit and engine PWB (YC506)
  1.8 seconds is less than one. (Only when the detection temperature is 50°C or more.) Deformed connector pin. Fix it
  Defective triac.  
    Broken fuser thermistor 2 wire. Replace the fuser unit 
    Fuser thermostat triggered. Reinsert the fuser unit 
    Broken fuser heater wire. Replace the fuser unit 
6000/ Broken fuser heater wire Deformed connec- If the l/F connector pins of the fuser unit and
6020/ Abnormally high fuser tor pin. the main unit are deformed owing to foreign
6030 thermistor temperature   matters, such as paper dusts, replace the con-
Com- Broken fuser thermistor   nectors or the units including the connectors.
bined wire Defective triac. Remove the power cord and check that the
      resistance between terminals T1 and T2 of the
      triac TRA51 is of several Mega-Ohms and not
      shorted. If failed, replace the
      power source PWB 
6220 Abnormally high fuser Shorted fuser Replace the fuser unit 
  thermistor 1 temperature thermistor 1.  
  The temperature of the Defective engine Replace the engine PWB and check for correct
  fuser thermistor 1 detects PWB. operation 
  255°C/491°F or more con-    
  tinuously for 3 s.    
6230 Broken fuser thermistor 1 Defective connec- Reinsert the connector. Also check for continu-
  wire tor cable or poor ity within the connector cable. If none, remedy
  average AD value input contact in the con- or replace the cable.
  from fuser thermistor 1 for nector. Fuser unit and engine PWB (YC506)
  1.8 seconds is less than Broken fuser Replace the fuser unit 
  one. thermistor 1 wire.  
    Fuser thermostat Reinsert the fuser unit 
    triggered.  
    Broken fuser Replace the fuser unit 
    heater wire.  
6400 Zero-cross signal error The zero-cross signal does not reach the engine PWB for more than 2 s. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Power source PWB (YC103) and connect-L PWB (YC1) Connect-L PWB (YC8) and engine PWB (YC503)
    Defective power source PWB. Replace the power source PWB and check for correct operation 
    Defective engine PWB. Replace the engine PWB and check for correct operation 
7000 Toner motor lock error During driving the toner motor, a motor overcurrent Lump of toner inside toner container. Replace the toner container.
  signal is detected for 5 s. Defective drive transmission system of the toner motor. Replace the developing unit 
    Defective toner motor. Replace the developing unit 
    Defective engine PWB. Replace the engine PWB and check for correct operation 
7410 Drum unit non- installing error The drum unit is not installed. Install the drum unit 
  The drum unit is not installed or not installed properly. The drum PWB EEPROM does not communicate normally. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Drum PWB (YC1) and connect-L PWB (YC3)
  Defective drum PWB EEPROM. Replace the drum unit 
    Defective engine PWB. Replace the engine PWB and check for correct operation 
9500 BRU communication error IPU PWB error Contact the Service Administrative Division.
9510 BRU PWB error    
9520 BRU PWB data error    
F000 Main PWB - operation panel PWB communication error Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective operation panel PWB. Replace the operation panel PWB.
F020 Main PWB RAM checksum error Defective main memory (RAM) on the main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective expanded memory (DIMM). Replace the expanded memory (DIMM).
F04Q Main PWB - engine PWB communication error Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective engine PWB. Replace the engine PWB.
F041 Main PWB - scanner communication error Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
F050 Engine ROM checksum error Defective engine PWB. Replace the engine PWB and check for correct operation 
F051 Scan engine ROM checksum error Defective engine PWB. Replace the engine PWB and check for correct operation 

Kyocera FS-3040MFP+, FS-3140MFP+ ошибка C0030, C0070, C0100, C0120, C0130, C0140, C0150, C0170, C0180, C0420, C0830, C0840, C0870, C0920, C1010, C2000,
C2200, C3100, C3200, C3300, C3500, C4000, C4200, C4700, C5100, C6000, C6020, C6030, C6000, C6020,
C6030, C6220, C6230, C6400, C7000, C7410, C9500, C9520, CF000, CF020, CF04Q, CF041, CF050, CF051, как сбросить ошибку



Главная | Каталог | Услуги | Наши клиенты | Контакты | Техподдержка | Полезная информация