Коды ошибок Kyocera FS-3040MFP+, FS-3140MFP+ |
|
Код
ошибки |
Неполадки |
Причина |
Устранение |
0030 |
FAX
control PWB system error Processing with the fax software
was disabled due to a hardware problem. |
Defective
FAX control PWB. |
Replace
the fax control PWB and check for correct operation. |
0070 |
FAX control PWB incompatible detection error Abnormal detection of FAX control PWB incompatibility In the
initial communication with the FAX control PWB, any normal communication
command is not transmitted. |
Defective
FAX software. |
Install the fax
software. |
Defective FAX control PWB. |
Replace
the fax control PWB and check for correct operation. |
0100 |
Backup memory device error |
Defective
flash memory. |
Replace the
main PWB and check for correct operation |
Defective main PWB. |
Replace the
main PWB and check for correct operation |
0120 |
MAC address data error For
data in which the MAC address is invalid. |
Defective
flash memory. |
Replace the
main PWB and check for correct operation |
Defective engine PWB, |
Replace the
engine PWB and check for correct operation |
0130 |
Backup memory read/ write error (main PWB) |
Defective
flash memory. |
Replace the
main PWB and check for correct operation |
Defective main PWB. |
Replace the
main PWB and check for correct operation |
0140 |
Backup memory data error (main PWB) |
Defective
flash memory. |
Replace the
main PWB and check for correct operation |
Defective main , PWB. |
Replace the
main PWB and check for correct operation |
0150 |
Engine PWB EEPROM error Detecting
engine PWB EEPROM communication error. |
Improper
installation engine PWB EEPROM. |
Check
the installation of the EEPROM and remedy if necessary. |
Defective engine PWB. |
Replace the
engine PWB and check for correct operation |
Device damage of EEPROM. |
Contact the Service
Administrative Division. |
0170 |
Billing counting error A
checksum error is detected in the main and engine backup memories for the
billing counters. |
Data
damage of EEPROM. |
Contact the Service
Administrative Division. |
Defective PWB. |
Replace
the main PWB or the engine PWB and check for correct operation |
0180 |
Machine
number mismatch Machine number of main and engine does
not match. |
Data
damage of EEPROM. |
Contact the Service
Administrative Division. |
0420 |
Paper feeder communication error Communication error between engine PWB and optional paper
feeder. |
Improper
installation paper feeder. |
Follow installation
instruction carefully again. |
Defective connector cable or poor contact in
the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Paper feeder interface and connect-L PWB (YC2)
Connect-L PWB (YC6) and engine PWB (YC504) |
Defective engine PWB. |
Replace the
engine PWB and check for correct operation |
Defective PF main PWB. |
Replace
the PF main PWB (Refer to the service manual for the paper feeder). |
0830 |
FAX control PWB flash program area checksum
error A checksum error occurred with the program of the
FAX control PWB. |
Defective
FAX software. |
Install the fax
software. |
Defective FAX control PWB. |
Replace the FAX control PWB |
0840 |
Faults of RTC The time is
judged to go back based on the comparison of the RTC time and the current
time or five years or more have passed. |
The
battery is disconnected from the main PWB. |
Check visually and
remedy if necessary |
Defective main PWB. |
Replace the
main PWB and check for correct operation |
0870 |
FAX control PWB to main PWB high capacity data
transfer error High-capacity data transfer between the
FAX control PWB and the main PWB of the machine was not normally performed
even if the data transfer was retried the specified times. |
Improper
installation FAX control PWB. |
Reinstall the FAX control PWB |
Defective FAX control PWB or main PWB. |
Replace
the FAX control PWB or main PWB and check for correct operation |
0920 |
Fax
file system error The backup data is not retained for
file system abnormality of flash memory of the FAX control PWB. |
Defective
FAX control PWB. |
Replace
the FAX control PWB and check for correct operation |
1010 |
Lift motor error During
driving the lift motor, a motor overcurrent signal is detected for 5 s. This
error is detected five times successively. |
Defective
bottom plate elevation mechanism in the cassette. |
Check
to see if the bottom plate can move smoothly and repair it if any problem is
found. |
Defective connector cable or poor contact in
the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Lift motor and connect-R PWB (YC8) Connect-R PWB
(YC2) and engine PWB (YC502) |
Defective drive transmission system of the lift
motor. |
Check
if the gears rotate smoothly. If not, grease the bushes and gears. Check for
broken gears and replace if any. |
Defective lift motor. |
Replace the lift
motor |
Defective engine PWB or connect-R PWB. |
Replace
the engine PWB or connect-R PWB and check for correct operation |
2000 |
Main motor steady-state error The
main motor ready input is not given for 2 s during the main motor is ON. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Main motor and engine PWB (YC501) |
Defective drive transmission system of the main
motor. |
Check
if the rollers and gears rotate smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if any. |
Defective main motor. |
Replace the main
motor. |
Defective engine PWB. |
Replace
the engine PWB and check for correct operation |
2200 |
Drum motor steady-state error The
drum motor ready input is not given for 2 s during the drum motor is ON. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Drum motor and engine PWB (YC11) |
Defective drive transmission system of the drum
motor. |
Check
if the rollers and gears rotate smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if any. |
Defective drum motor. |
Replace the drum
motor. |
Defective engine PWB. |
Replace the
engine PWB and check for correct operation |
3100 |
ISU
home position error The home position is not correct when
the power is turned on or at the start of copying using the table. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Home position sensor and CCD PWB (YC3) CCD PWB
(YC2) and main PWB (YC8) ISU motor and main PWB (YC1004) |
|
|
Defective
home position sensor. |
Replace the home
position sensor. |
|
|
Defective
ISU motor. |
Replace the ISU
motor. |
|
|
Defective
CCD PWB. |
Replace the scanner unit |
|
|
Defective
main PWB. |
Replace the
main PWB and check for correct operation |
3200 |
Exposure
lamp error When input value at the time of exposure lamp
illumination does not exceed the threshold value between 5 s. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. LED PWB (YC1) and LED drive PWB (YC2) LED drive
PWB (YC1) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8) |
|
|
Defective
exposure lamp or LED drive PWB. |
Replace the scanner unit |
|
|
Defective
CCD PWB. |
Replace the scanner unit |
|
|
Defective
main PWB. |
Replace the
main PWB and check for correct operation |
3300 |
AGC
error After AGC, correct input is not obtained at CCD. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Inverter PWB (YC101) and CCD PWB (YC3) CCD PWB
(YC2) and main PWB (YC8) |
|
|
Defective
exposure lamp or inverter PWB. |
Replace the scanner unit |
|
|
Defective
CCD PWB. |
Replace the scanner unit |
|
|
Defective
main PWB. |
Replace the
main PWB and check for correct operation |
3500 |
Communication error between scanner and ASIC An error code is detected. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. CCD PWB (YC2) and main PWB (YC8) |
Defective CCD PWB. |
Replace the scanner unit |
Defective main PWB. |
Replace
the main PWB and check for correct operation (see page 1-5-34). |
4000 |
Polygon motor synchronization error The polygon motor ready input is not given for 10 s during the
polygon motor is ON. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Laser scanner unit and main PWB (YC14) |
Defective polygon motor. |
Replace the laser scanner unit |
Defective main PWB. |
Replace the
main PWB and check for correct operation |
4200 |
BD steady-state error |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Laser scanner unit and main PWB (YC16) |
Defective laser scanner unit. |
Replace
the laser scanner unit (see page 1-5-16). |
Defective main PWB. |
Replace the
main PWB and check for correct operation |
4700 |
VIDEO ASIC device error Mismatch
of reading data from two locations occurs eight times successively. Mismatch
between writing data and reading data occurs eight times successively. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
replace the cable. Main PWB (YC13) and engine PWB (YC12) |
Defective main PWB or engine PWB. |
Replace
the main PWB or the engine PWB and check for correct operation |
5100 |
Main charger high-volt-age error Five pages have been printed with the main charger output
short-circuited. |
Drum
unit installed incorrectly. |
Verify harness is not
pinched. |
Engine PWB installed incorrectly. |
Verify harness is not
pinched. |
Defective engine PWB. |
Replace the
engine PWB and check for correct operation |
6000 |
Broken
fuser heater wire The temperature does not reach
100°C/212°F after the fuser heater has been turned on continuously for |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Fuser heater and power source PWB (YC102) Fuser
unit and engine PWB (YC506) |
|
30 s. The temperature
does not rise by 1°C/1.8°F after the fuser heater lamp has been |
Deformed
connector pin. |
Fix it |
|
Defective triac. |
|
|
turned on continuously for 15 s during warm-up or at
standby.(Only when the detection temperature is less than 200°C.) |
Fuser
thermostat triggered. |
Reinsert the fuser unit |
|
Broken
fuser heater wire. |
Replace the fuser unit |
6020 |
Abnormally
high fuser thermistor 2 temperature |
Shorted
fuser thermistor 2. |
Replace the fuser unit |
|
The temperature of the
fuser thermistor 2 detects 250°C/482°F or more continuously for 3 s. |
Deformed
connector pin. |
Fix it |
|
Defective triac. |
|
|
|
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
6030 |
Broken
fuser thermistor 2 wire average AD value input from fuser
thermistor 2 for |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Fuser unit and engine PWB (YC506) |
|
1.8 seconds is less
than one. (Only when the detection temperature is 50°C or more.) |
Deformed
connector pin. |
Fix it |
|
Defective triac. |
|
|
|
Broken
fuser thermistor 2 wire. |
Replace the fuser unit |
|
|
Fuser
thermostat triggered. |
Reinsert the fuser unit |
|
|
Broken
fuser heater wire. |
Replace the fuser unit |
6000/ |
Broken fuser heater
wire |
Deformed connec- |
If the l/F connector
pins of the fuser unit and |
6020/ |
Abnormally high fuser |
tor pin. |
the main unit are deformed owing to
foreign |
6030 |
thermistor temperature |
|
matters, such as paper dusts, replace
the con- |
Com- |
Broken fuser thermistor |
|
nectors or the units including the
connectors. |
bined |
wire |
Defective triac. |
Remove the power cord
and check that the |
|
|
|
resistance between terminals T1 and
T2 of the |
|
|
|
triac TRA51 is of several Mega-Ohms
and not |
|
|
|
shorted. If failed, replace the |
|
|
|
power
source PWB |
6220 |
Abnormally high fuser |
Shorted fuser |
Replace the fuser unit |
|
thermistor 1 temperature |
thermistor 1. |
|
|
The temperature of the |
Defective engine |
Replace the engine
PWB and check for correct |
|
fuser thermistor 1 detects |
PWB. |
operation |
|
255°C/491°F or more con- |
|
|
|
tinuously for 3 s. |
|
|
6230 |
Broken fuser
thermistor 1 |
Defective connec- |
Reinsert the
connector. Also check for continu- |
|
wire |
tor cable or poor |
ity within the connector cable. If
none, remedy |
|
average AD value input |
contact in the con- |
or replace the cable. |
|
from fuser thermistor 1 for |
nector. |
Fuser unit and engine PWB (YC506) |
|
1.8 seconds is less than |
Broken fuser |
Replace the fuser unit |
|
one. |
thermistor 1 wire. |
|
|
|
Fuser thermostat |
Reinsert the fuser unit |
|
|
triggered. |
|
|
|
Broken fuser |
Replace the fuser unit |
|
|
heater wire. |
|
6400 |
Zero-cross
signal error The zero-cross signal does not reach the
engine PWB for more than 2 s. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Power source PWB (YC103) and connect-L PWB (YC1)
Connect-L PWB (YC8) and engine PWB (YC503) |
|
|
Defective
power source PWB. |
Replace
the power source PWB and check for correct operation |
|
|
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
7000 |
Toner
motor lock error During driving the toner motor, a motor
overcurrent |
Lump
of toner inside toner container. |
Replace the toner
container. |
|
signal is detected for 5 s. |
Defective
drive transmission system of the toner motor. |
Replace the developing unit |
|
|
Defective
toner motor. |
Replace the developing unit |
|
|
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
7410 |
Drum
unit non- installing error |
The
drum unit is not installed. |
Install the drum unit |
|
The drum unit is not
installed or not installed properly. The drum PWB EEPROM does not communicate
normally. |
Defective
connector cable or poor contact in the connector. |
Reinsert
the connector. Also check for continuity within the connector cable. If none,
remedy or replace the cable. Drum PWB (YC1) and connect-L PWB (YC3) |
|
Defective
drum PWB EEPROM. |
Replace the drum unit |
|
|
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
9500 |
BRU
communication error |
IPU PWB error |
Contact the Service
Administrative Division. |
9510 |
BRU PWB error |
|
|
9520 |
BRU PWB data error |
|
|
F000 |
Main
PWB - operation panel PWB communication error |
Defective
main PWB. |
Turn
the main power switch off/on to restart the machine. If the error is not
resolved, replace main PWB. |
|
|
Defective
operation panel PWB. |
Replace the operation
panel PWB. |
F020 |
Main
PWB RAM checksum error |
Defective
main memory (RAM) on the main PWB. |
Turn
the main power switch off/on to restart the machine. If the error is not
resolved, replace main PWB. |
|
|
Defective
expanded memory (DIMM). |
Replace the expanded
memory (DIMM). |
F04Q |
Main
PWB - engine PWB communication error |
Defective
main PWB. |
Turn
the main power switch off/on to restart the machine. If the error is not
resolved, replace main PWB. |
|
|
Defective
engine PWB. |
Replace the engine
PWB. |
F041 |
Main
PWB - scanner communication error |
Defective
main PWB. |
Turn
the main power switch off/on to restart the machine. If the error is not
resolved, replace main PWB. |
F050 |
Engine
ROM checksum error |
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
F051 |
Scan
engine ROM checksum error |
Defective
engine PWB. |
Replace the
engine PWB and check for correct operation |
|
|
|
|
|
|
|